GENERAL
SM6000
8 / 21
DELTA ELEKTRONIKA B.V.
rev. Nov. 2020
3.14
STATUS OUTPUTS
All the status outputs are logic outputs. Logic "0" means the
output is 0 V, logic "1" means the output is 5 V (Ro = 500
Ohm). This makes it possible to drive directly: an opto-
coupler, a TTL gate or a CMOS gate.
The Limit Status or
LIM-status
is "1" in case the DC output
voltage or current reaches the limit setting. Which limit circuit
is active can be seen on the front panel LED’s.
The Over Temperature Status or
OT-stat
us is "1" in case of
an over temperature, the OT LED will be on and the output
shuts down. As a pre-warning the OT LED starts to blink
when the unit runs hot but the situation of over temperature is
not reached yet. The status will still be low when the LED is
blinking.
The Current Control Status or
CC-status
output is "1" when
the unit is in CC-mode.
The Power Sink OverLoad Status or
PSOL-status
output is
"1" when the optional Power Sink is overloaded or
overheated.
The AC-Fail Status or
ACF-status
output is "1" in case of
Phase Loss or when the mains voltage is below 340 VAC.
The DC-Fail Status or
DCF-status
output is "1" when the DC
output voltage is either 5% below or above the set point.
When the unit is in CC-mode, DCF will always be "1", see
previous paragraph .
3.15
STATUS RELAY OUTPUTS
The power supply has 2 status relay outputs, with each a
change-over contact. They are connected to connector CON
D. The pins 1,2,3 are connected to the DCF-relay and pins
4,5,6 to the ACF-relay (see fig. 3 - 10).
fig 3 - 10
Status relay outputs on CON D. This situation gives
the relay positions during fault condition.
fig 3 – 8 Location of output terminals and analog programming connector on the rear panel.
CON A
Interlock Connector
CON B
Master connector for Master / Slave operation (output)
CON C
Slave connector for Master / Slave operation (input)
CON D
Relay Outputs, contacts 1 - 6
CON E
Analog Programming Connector ( not available on SM300-20 / SM600-10, see CON H)
CON F
PSC-232, from PC or previous PSC (optional)
CON G
PSC-232, to next PSC (optional)
CON H
PSC-488 (optional) or ISO AMP CARD (optional)
SM300-20 / SM600-10 standard with ISO-AMP instead of CON E.
SW 1
Various settings, see table at the bottom of this page.
SW 2
Settings for PSC-488 and PSC-232 (optional)
fig 3 -9 Connectors and switches on the rear panel.
Switch no.
UP position
DOWN position
Default Setting
SW 1
– 1
Programming via 15pole connector CON E
(analog).
Optional programming with e.g. PSC-232, PSC-488,
ISO AMP CARD
Up
SW 1
– 2
‘Output On’ after mains on
‘Output Off’ after mains on
Down
SW 1
– 3
DCF LED enabled
DCF LED disabled
(DCF status and DCF relay are still enabled)
Up
SW 1
– 4
Parallel Master / Slave operation
Series Master / Slave operation
Up
SW 1
– 5*
After switching mains on, the unit will start with
the same settings for the voltage and the
current as it had before switching mains off
After switching mains on, the unit will always start up
with a voltage setting of 0 V and a current setting of 0
A. Once the unit is switched on, the voltage and current
can be set to the preferred value.
Down
* = SW1-5 only on SM300-20 / SM600-10 and on units with optional digital encoders (option P220).