REMOTE PROGRAMMING
SM3300
22 / 30
DELTA ELEKTRONIKA B.V.
rev. Jan. 2022
7
REMOTE PROGRAMMING
7.1
SOURCE SETTINGS
Via the front menu, the source can be set to the required
programming input via: Menu -> Configuration -> Source.
The possible settings for V-settings, I-settings and P-
settings are: front encoders, ethernet, web interface,
sequencer or an optional interface in rear slot1, 2, 3 or 4.
It is possible to have different sources for the settings for
example V-settings via 'web' and I-settings via 'front'.
7.2
WEB INTERFACE
It is advised to use the web browsers Mozilla Firefox or
Google Chrome.
The web interface is available 40 seconds after start up of
the unit.
Set the programming source for voltage and/or current to
'web' via the front menu.
The below menu items are available in the web interface:
7.2.1
CONSOLE
FRONTPANEL
Possible settings via the console:
- voltage and current
- output On/Off
Possible monitoring via the console:
- actual and set values of voltage and current
- output setting (on/off)
- status icons, for example DC-fail
- type of unit and serial number
- on time of the unit
- system temperature and fan speed
- input voltage
See fig. 7 - 1 for the console lay-out.
SEQUENCER
Possible to select sequences from
the unit memory.
Running, Pausing and Stopping of
sequences.
Trigger sequence
Running in Single Step mode.
See fig 7 - 2 for the console lay-out.
MASTER / SLAVE
Only available on the Master unit.
Overview of the entire system.
Shows the most important icons.
Links to the front panels of Slave units when the Slave(s)
are connected to the same LAN. (Click ID#)
See fig 7 - 3 for the console lay-out.
7.2.2
CONFIGURATION
GENERAL
FRONTPANEL
Front user interface language.
Front unlock key protected (Enabling will lock
Frontpanel).
Backlight intensity when active.
Backlight intensity when no user interaction.
Timeout for backlight dimmer.
LCD contrast.
DEFAULTS
Default voltage setting and value after power cycle.
Default current setting and value after power cycle.
Default output state after power cycle.
SOURCES
Set the program source for voltage control.
Set the program source for current control.
fig 7 - 1
Front console for setting of the output and
monitoring various parameters.
fig 7 - 2
Sequencer console for selecting and controlling
sequences.