- 65 -
Address Type
Input Register description
AP ED RE AL
6036 +
200
x
(
N
-1) W
Measurement unit of the quantity associated to channel
N
if the
channel is configured as 0…1 V input (HD35EDH). See TAB 10.1
9
6037 +
200
x
(
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel
is configured as 0…1 V input (HD35EDH):
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
9
6038 +
200
x
(
N
-1) W
Measurement unit of the quantity associated to channel
N
if the
channel is configured as 0…50 mV (HD35EDH). See TAB
10.1
9
6039 +
200
x
(
N
-1) SW
Resolution of the quantity associated to channel
N
if the channel
is configured as 0…50 mV (HD35EDH):
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
9
6040 +
200
x
(
N
-1) W
Measurement unit of the quantity associated to channel
N
if the
channel is configured as 4…20 mA input (HD35EDH). See TAB
10.1
9
6041 +
200
x
(
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel
is configured as 4…20 mA input (HD35EDH):
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
9
6042 +
200
x
(
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the
channel is configured as potentiometric input (HD35EDH). See
TAB
10.1
9
6043 +
200
x
(
N
-1) SW
Resolution of the quantity associated to channel
N
if the channel
is configured as potentiometric input (HD35EDH):
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
9
9002 W
Measurement unit of the quantity associated to channel
N
if the
channel is configured as counter (HD35EDH). See TAB
10.1
9
9003 SW
Resolution of the quantity associated to channel
N
if the channel
is configured as counter (HD35EDH):
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
9
General information
10000
W
Year of last measurement.
9
10001
W
Month of last measurement.
9
10002
W
Day of last measurement.
9
10003
W
Hour of last measurement.
9
10004
W
Minutes of last measurement.
9
10005
W
Seconds of last measurement.
9
10006
W
Packet Error Rate in % of the device (x10).
9
9
9
10007
W
Number of RF hops of the last transmitted packet.
9
9
9
10008
SW RF signal level in dBm (relating to last RF hop).
9
9
9
10009 W
Battery level:
0=empty, 1=half full , 2=full, 3=external power supply
9
9
9
9
10010
W
Time, in seconds, elapsed since the last transmitted packet.
9
9
9
10011
W
RF signal level expressed as 0 to 7 scale.
9
9
9
10012
W
Modbus address of the AP to which the device is connected.
9
9
9
10013 W
Password level for the current connection:
0=no password, 1=user level, 2= administrator level
9
10014
W
Battery remaining capacity in %.
9
9
10015
W
Estimation of battery remaining capacity in hours (x10).
9
9
10016
W
Type of power supply: 0=battery, 1=USB, 2=ext. power supply
9
9
10017
W
Estimation of battery remaining capacity in weeks
9
9
10018 W
Alarm relay #1 status:
0=deactivated, 1=intermittent, 2=active, 3=undetermined
9
10019 W
Alarm relay #2 status:
0=deactivated, 1=intermittent, 2=active, 3=undetermined
9