background image

 

HD33[L]M.GSM

 

-   16   - 

V1.10

 

LPPYRA10 

"Secondary standard" pyranometer according to ISO 9060. Output in 

µV/(Wm

-2

). Supplied with protection shield, cartridge for silica gel crystals, 2 

spare charges, bubble level for alignment, connector and Calibration Report. 

On request 5 or 10 m cables with connector. 

LPSILICON- 

Pyranometer with silicon photodiode for measuring the global solar irradiance, 

PYRA 04 

diffuser for cosine correction. Spectral range 350...1100 nm. Typical 
sensitivity: 10 

μ

V/W m

-2

. Measuring range: 0…2000 W/m

2

. Fixed cable 5 m 

long, terminated with open wires.

 

LPSP2 

Shade disk for LPPYRA03. 

LPS1 

Attachment bracket for LPPYRA02 and LPPYRA10, suitable for mast 

 40 ÷ 

50 mm. 

LPS3 

Attachment bracket for LPPYRA03, suitable for mast 

 40 ÷ 50 mm. 

R

AIN GAUGES

 

HD2013 

Tipping bucket rain gauge, 400cm

area, for temperature ranging from 4 °C 

to +60 °C. Standard resolution 0.2 mm. 0.1 or 0.5 mm on request with 
order. Normally closed output contact. 

HD2013R 

Tipping bucket rain gauge, 400cm

area, with heater for temperature ranging 

from -20 to +60 °C. Standard resolution 0.2 mm. 0.1 or 0.5 mm on request 
with order. Normally closed output contact. Power supply: 12 Vdc or 24 Vdc 
± 10% / absorbed power 165 W. 

HD2015 

Tipping bucket rain gauge, 200cm

area, for temperature ranging from 4 °C 

to +60 °C. Standard resolution 0.2 mm. 0.1 or 0.5 mm on request with 

order. Normally closed output contact. 

HD2015R 

Tipping bucket rain gauge, 200cm

area, with heater for temperature ranging 

from -20 to +60 °C. Standard resolution 0.2 mm. 0.1 or 0.5 mm on request 
with order. Normally closed output contact. Power supply: 12 Vdc or 24 Vdc 
± 10% / absorbed power 50 W. 

HD2016 

Weighing rain gauge, area 400 cm

2

. 3000 cc collecting reservoir. Automatic 

water discharge when the amount of water collected exceeds a configurable 

percentage of the reservoir capacity (by default 10%, corresponding to 
300 cc). Operating temperature from +4 °C to +60 °C. RS485 Modbus-RTU 

or SDI-12 output. Voltage-free output contact (NO). Power supply: 
10…15 Vdc. Adjustable feet for ground installation included in the kit. 

HD2016R 

Weighing rain gauge, area 400 cm

2

. 3000 cc collecting reservoir. Automatic 

water discharge when the amount of water collected exceeds a configurable 
percentage of the reservoir capacity (by default 10%, corresponding to 

300 cc). Operating temperature from -20 °C to +60 °C.  RS485 Modbus-RTU 

or SDI-12 output. Voltage-free output contact (NO).  Power supply: 10…15 Vdc 
for the measuring circuit, 12 Vdc / 90 W for the heater. Adjustable feet for 

ground installation included in the kit. 

HD2013.18

 Bird 

dissuader. 

HD2013.5K

 

Kit of accessories for the installation of the HD2013 rain gauge raised 

500 mm from the ground and the levelling. 

HD2013.5K.1

 

Kit of accessories for the installation of the HD2013 rain gauge raised 1 m 

from the ground and the levelling. 

HD2015.5K

 

Kit of accessories for the installation of the HD2015 rain gauge raised 

500 mm from the ground and the levelling. 

HD2015.5K.1

 

Kit of accessories for the installation of the HD2015 rain gauge raised 1 m 

from the ground and the levelling. 

HD2016.33K

 

Kit of accessories for the installation of the HD2016 rain gauge raised 

500 mm from ground and the levelling. 

Summary of Contents for HD33[L]M.GSM

Page 1: ...Operating manual GSM Data Logger HD33 L M GSM Keep for future reference www deltaohm com English Companies Brands of GHM...

Page 2: ...TECHNICAL CHARACTERISTICS 5 4 MEASURING PROBES 7 5 SIM CARD 8 6 INSTALLATION 9 7 POWER SUPPLY 9 8 USB CONNECTION 10 9 HD35AP S SOFTWARE 10 10 SMS COMMANDS 11 11 GPRS TCP IP CONNECTION 13 12 STORAGE OF...

Page 3: ...o GSM GPRS transmission the user will not have to remove the data logger from its position or reach the place where the data logger is installed to download the data measured with the PC the instrumen...

Page 4: ...or LED red blinking indicates that the instrument is powered blinks green to signal the GSM activity 4 Custom LCD display The cyclic automatic scrolling of the measurements can be set with the HD35AP...

Page 5: ...Weight 1 kg approx including shield and fixing clamping Housing Dimensions 122 x 120 x 56 mm excluding external antenna Material Polycarbonate PC Protection degree IP 67 with protective cap on the US...

Page 6: ...tes to an hourly value For the other characteristics please refer to the data sheet of the chosen rain gauge A measurement compensation curve as a function of the rainfall rate can be configured Wind...

Page 7: ...lable Solar radiation The pyranometers LP PYRA 02 LP PYRA 03 LP PYRA 10 LP SILICON PYRA 04 etc with mV output signal can be connected Wind speed and direction For the measurement of wind speed and dir...

Page 8: ...t the SIM tray back in place and push the metal block in the direction of the arrow LOCK 6 Close again the housing by fixing the 4 front screws Through the HD35AP S software set the necessary informat...

Page 9: ...th direct voltage from 7 to 30 Vdc and can be powered by mains through the power supply unit HD32MT SWD or by a solar panel through the power supply unit HD32WSF S12 that includes a 12 Vdc 7 2 Ah batt...

Page 10: ...it is not powered by the PC USB port When the data logger is not connected to the PC replace the mini USB connector protective cap to ensure the watertight integrity of the instrument 9 HD35AP S SOFTW...

Page 11: ...of measurement data via FTP FTP OFF Deactivates the periodic download of measurement data via FTP FTP PERIOD period index Set the transmission interval via FTP where period index 0 15 min 1 30 min 2 1...

Page 12: ...date where YYYY year MM month DD day HH hour MM minutes SS seconds HTTP DL INTERVAL YYYY MM DD HH MM SS YYYY MM DD HH MM SS Uploads on the HTTP server all data between the specified dates where YYYY y...

Page 13: ...he Modem Router 4 Disconnect the data logger from the USB port 5 In the HD35AP S software select Tools Type of connection select the TCP server option and set the number of the port opened in the Mode...

Page 14: ...safety technical conditions The regular functioning and operational safety of these instruments can be ensured only if all normal safety measures as well as the specific measures described in this man...

Page 15: ...K sensor temperature probe Measuring range 40 105 C Probe stem AISI 304 14 mm length 150 mm Cable length 2 5 or 10 m standard 4 pole M12 female connector HD9007A 1 12 ring protection against solar rad...

Page 16: ...ion 0 2 mm 0 1 or 0 5 mm on request with order Normally closed output contact Power supply 12 Vdc or 24 Vdc 10 absorbed power 50 W HD2016 Weighing rain gauge area 400 cm2 3000 cc collecting reservoir...

Page 17: ...itions 40 60 C 0 100 RH Rod mounting Dimensions 210 x 120 mm HD54 9K Transverse mast kit including transverse mast 40 mm and L 1500 mm two extension bars 40 mm and accessories ACCESSORIES HD35AP CFR21...

Page 18: ...n be fixed on a flat base with screws or to the ground with pegs Foldable legs for the transport HD2005 20 1 Tripod kit with adjustable legs for installing environmental sensors pyranometers temperatu...

Page 19: ......

Page 20: ...third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic eq...

Page 21: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Page 22: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V1 10 10 10 2018...

Reviews: