HD35
- 105 -
V1.12
Address Type
Input Register description
AP ED RE AL
110
SW S
OIL VOLUMETRIC WATER CONTENT
(VWC) in % (x10) – channel 2.
111
B
Soil volumetric water content
alarm – channel 2:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
112
SW VWC
PROBE OUTPUT
in mV (x10) – channel 2.
113
B
VWC probe output alarm – channel 2:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
114
SW S
OIL VOLUMETRIC WATER CONTENT
(VWC) in % (x10) – channel 3.
115
B
Soil volumetric water content
alarm – channel 3:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
116
SW VWC
PROBE OUTPUT
in mV (x10) – channel 3.
117
B
VWC probe output alarm – channel 3:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
118
SW A
IR SPEED
(HD404…SR transmitter) in m/s (x100).
119
B
Air speed (HD404…SR transmitter) alarm:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
120
SW PAR
(Photosynthetically Active Radiation) in µmol/(m
2
s).
121
B
PAR alarm:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
122
SW R
AINFALL QUANTITY IN THE LAST HOUR
in counts.
123
B
Alarm for rainfall quantity in the last hour:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
Measured values and status of measurement alarms for configurable inputs
1000 +
200
x
(N-1) SW
T
EMPERATURE
with 2-wire Pt100 sensor of channel N in the set
measurement unit (x10).
1001 +
200
x
(N-1)
B
Alarm for temperature with 2-wire Pt100 sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1002 +
200
x
(N-1) SW
T
EMPERATURE
with 3-wire Pt100 sensor of channel N in the set
measurement unit (x10).
1003 +
200
x
(N-1)
B
Alarm for temperature with 3-wire Pt100 sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1004 +
200
x
(N-1) SW
T
EMPERATURE
with 4-wire Pt100 sensor of channel N in the set
measurement unit (x10).
1005 +
200
x
(N-1)
B
Alarm for temperature with 4-wire Pt100 sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1006 +
200
x
(N-1) SW
T
EMPERATURE
with 2-wire Pt1000 sensor of channel N in the set
measurement unit (x10).
1007 +
200
x
(N-1)
B
Alarm for temperature with 2-wire Pt1000 sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1008 +
200
x
(N-1) SW
T
EMPERATURE
with 3-wire Pt1000 sensor of channel N in the set
measurement unit (x10).
1009 +
200
x
(N-1)
B
Alarm for temperature with 3-wire Pt1000 sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1010 +
200
x
(N-1) SW
T
EMPERATURE
with 4-wire Pt1000 sensor of channel N in the set
measurement unit (x10).
1011 +
200
x
(N-1)
B
Alarm for temperature with 4-wire Pt1000 sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1012 +
200
x
(N-1) SW
T
EMPERATURE
with TC_K sensor of channel N in the set
measurement unit (x10).
1013 +
200
x
(N-1)
B
Alarm for temperature with TC_K sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1014 +
200
x
(N-1) SW
T
EMPERATURE
with TC_J sensor of channel N in the set
measurement unit (x10).
1015 +
200
x
(N-1)
B
Alarm for temperature with TC_J sensor of channel N:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.