HD35
- 74 -
V1.12
9.2
I
NSTALLATION OF WATERPROOF HOUSING
The housing for waterproof models can be fixed to a wall or, for outdoor installations, to a
40 mm
diameter mast by means of
HD2003.77/40 clamping
(for housing H=120 mm x L=80 mm)
.
Fig. 9.2.1: installation of waterproof housing
F
or outdoor installations
, use the optional protection shield against solar radiations (
for hous-
ing H=120 mm x L=80 mm
).
Data loggers supplied with clamping already mounted on the back of the housing are equipped
with protection devices against over-voltages connected to the clamping. For a correct opera-
tion of the protecting devices, the yellow/green wire with fast-on connector connected to the
clamping should be connected to ground.
The outdoor installation of the combined temperature and relative humidity probe requires
HD9007A-1 or HD9007A-2 protection against solar radiations.
9.3
C
ONNECTION TO THE WIRELESS NETWORK
The device can be connected and disconnected to/from the wireless network by pressing for
5 seconds the internal connection button (CONNECT/DISCONNECT button).
Fig. 9.3.1: internal connection button
If the device is disconnected, by pressing for 5 seconds the connection button the buzzer emits
a beep and the green RF LED blinks for 1 second to indicate the start of the connection proce-
dure. If the device belongs to a wireless network and the base unit is reachable, after connection
the buzzer emits a second beep and the green RF LED blinks during data transmission. If the de-
vice doesn’t belong to a wireless network and the base unit is not reachable, the second beep of
the buzzer is not emitted and the red RF LED will blink.
Plastic washers for thermal insulation of the
housing from metal parts
Connection
button