HD35
- 85 -
V1.12
TAB. 9.10.1: memory capacity of data loggers in waterproof housing
Model
Number of storable
samples
(**)
Minimum
logging interval
Stored quantities
(*)
HD35EDW
7P/1
TC
68,000
1 s
T
HD35EDW
7P/2
TC
from 52,000 to 68,000
2 s
(***)
T
HD35EDW
7P/3
TC
from 42,000 to 68,000
5 s
(***)
T
HD35EDW
N/1
TC
68,000
1 s
T
HD35EDW
N/2
TC
52,000
1 s
T
HD35EDW
N/3
TC
42,000
1 s
T
HD35EDW
N
TV
68,000
1 s
T
HD35EDW
K/4
TC
from 36,000 to 68,000
5 s
(***)
T
HD35EDW
1
TV
68,000
1 s
RH
HD35EDW
1
TVI
68,000
1 s
RH
HD35EDW
1N
TC
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
17P
TC
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
1N
TV
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
1N
TVI
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
1N/2
TC
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
14bN
TC
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35EDW
14b7P
TC
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35EDW
R
TC
42,000
1 s
R, D
R
, mV
HD35EDW
1NR
TC
24,000
1 s
T, RH, T
D
, AH, R, D
R
, mV
HD35EDW
7PR
TC
36,000
1 s
T, R, D
R
, mV
HD35EDW
1N7PR
TC
22,000
1 s
T, RH, T
D
, AH, R, D
R
, mV
HD35EDW
RP
TC
28,000
1 s
R, D
R
, mV, P, D
P
, I
P
HD35EDW
P
TC
36,000
1 s
P, D
P
, I
P
HD35EDW
NP
TC
28,000
1 s
T, P, D
P
, I
P
HD35EDW
1NP
TC
22,000
1 s
T, RH, T
D
, AH, P, D
P
, I
P
HD35EDW
1NL
TC
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, H
LEAF
HD35EDW
S
TC
52,000
1 s
T, VWC
HD35EDW
S/2
TC
36,000
1 s
T, VWC
HD35EDW
S/3
TC
26,000
1 s
T, VWC
HD35EDW
DP
TC
28,000
1 s
F
L
, P
REL
, P, D
P
, I
P
HD35EDW
1NI2
TCV
30,000
1 s
T, RH, T
D
, AH, I
HD35EDW
1NB…
TV
30,000
1 s
(
****
)
T, RH, T
D
, AH, CO
2
HD35EDW
1NB
..
I
..
TCV
26,000
1 s
(
****
)
T, RH, T
D
, AH, I, CO
2
HD35EDW1NB…F
TCV
26,000
1 s
(
****
)
T, RH, T
D
, AH, PAR, CO
2
HD35EDW
WBGT
22,000
2 s
T, T
NW
, T
G
, RH, T
D
, WBGT
HD35EDW
H
see below
5 s
(***)
depends on the inputs configuration
58,000 with only one input used (not as counter)
46,000 with two inputs used (not as counter) or one input used as counter
38,000 with three inputs used (not as counter) or two inputs one of which as counter
32,000 with four inputs used (not as counter) or three inputs one of which as counter
28,000 with four inputs used, one of which as counter
HD35EDW-MB
from 14,000 to 52,000
1 s
depends on the sensors connected
(*)
List of the quantities:
AH: absolute humidity
P
ATM
: atmospheric pressure
CO
2
: carbon dioxide
P
REL
: relative pressure
D
P
: daily rainfall quantity
PVP: partial vapour pressure
D
R
: daily solar radiation (Wh/m
2
)
R: solar radiation (pyranometer)
F
L
: fluid level
RH: relative humidity
H
LEAF
: leaf wetness
T: temperature
I: illuminance
T
D
: dew point
I
P
: rainfall rate (mm/h)
T
G
: globe thermometer temperature
MR: mixing ratio
T
NW
: natural ventilation wet bulb temperature
mV: pyranometer output in mV
T
W
: wet bulb temperature
P: rainfall quantity
WBGT: WBGT index
PAR: Photosintetically Active Radiation
VWC: soil volumetric water content
Summary of Contents for HD35AP series
Page 120: ...HD35 120 V1 12 HD35EDLM TC...
Page 141: ...NOTES...
Page 142: ...NOTES...
Page 143: ...NOTES...