1. Disconnect AC input from the charger, or from the 

wall outlet. Wait 30 seconds for the input relay to 

open.

2. While reconnecting AC input, press and hold the 

Select Charge Profile Button. Hold the button 

(approximately 10 seconds) through the light 

check function until Error Indicator is on (in 

amber) and Battery Charging Indicator (in green) 

starts flashing.

3. Press and release the Select Charge Profile Button 

to advance through charging profiles loaded on 

the charger. The selected charging profile will 

be displayed up to three times (e.g. “P-0-1-1” for 

Profile 11).* 

*Process will time out and profile will remain 

unchanged if there is 15 seconds of inactivity, a 

profile number is allowed to display three times, or if 

AC power is cycled. 

4. Once the desired charging profile is displayed, 

press and hold the Select Charge Profile button 

for 10 seconds to confirm selection and exit 

Profile Selection Mode. When the charge profile 

is confirmed, the Error Indicator and Battery 

Charging INdicator lights will turn off, while the 

blue AC Power Indicator remains lit. At this point, 

the button can be released.

5. Press the Select Charge Profile Button to check 

that the desired profile is selected.

2.0 IC650 Configuration

There are two ways to alter the configuration on the IC650 Charger:

1.  Use the Select Charge Profile Button.

2.  Use a pre-programmed USB flash drive.

Figure 1.Disconnect AC input from the charger.

2.1 Selecting A Charge Profile Using the ‘Select Charge Profile Button’

Figure 2. Reconnect AC input while holding the 

Select Charge Profile Button.

Figure 3. Press the Select Charge Profile Button 

to advance through the charge profiles. When the 

desired charge profile appears, hold the button for 10 

seconds to confirm your selection.

Summary of Contents for IC650

Page 1: ...650W Industrial Battery Charger Delta Q Technologies Corp 3755 Willingdon Avenue Burnaby BC V5G 3H3 CANADA Web www delta q com Phone 1 604 337 1110 E mail support delta q com 2015 Delta Q Technologies...

Page 2: ...Delta Q IC650 Troubleshooting Guide Table of Contents 1 0 Charger Interface 4 2 0 IC650 Configuration 6 3 0 Charger Fault Codes 8 4 0 Charger Error Codes 9...

Page 3: ...e Charge Profile Error Display shows one of four possible codes to indicate different conditions F codes mean that an internal fault condition has caused charging to stop E codes mean that an external...

Page 4: ...5 1 1 Normal Operation Bulk charging 80 complete 1 2 Absorption Finish phase 80 complete 1 3 Charging complete...

Page 5: ...ile is displayed press and hold the Select Charge Profile button for 10 seconds to confirm selection and exit Profile Selection Mode When the charge profile is confirmed the Error Indicator and Batter...

Page 6: ...port from the AC connection DC disconnected or from the DC connection AC disconnected 2 If there is enough disk space about 2 mb the charger will write charge tracking data to the drive The Fault Erro...

Page 7: ...analysis F 0 0 1 PFC failure PFC Excessive Leakage Fault Internal charger fault Remove AC and battery for minimum 30 seconds and retry charger If fault persists contact the manufacturer of your vehic...

Page 8: ...s Replace battery pack Check DC connections Charger output reduced due to high temperatures This error will automatically clear once the charger is reset by cycling DC E 0 0 4 Battery defective Batter...

Page 9: ...external controller over the CANbus network contact OEM for instruction E 0 1 6 E 0 1 8 E 0 1 9 E 0 2 6 Software error The software update failed Ensure the USB Flash Drive is properly formatted and...

Page 10: ...11 Delta Q IC650 650W Industrial Battery Charger www delta q com...

Reviews: