Delta-Q QuiQ 1500 Charger Manual

Troubleshooting Instructions

If a fault occurs, count the number of red flashes between pauses and refer to the table below.

Flashes

Cause

Solution

Battery high voltage

Check battery size and condition. This fault will 

clear automatically once the condition has been 

corrected.

Battery low voltage

Check battery size and condition. This fault will 

clear automatically once the condition has been 

corrected.

Charge timeout caused by 

battery pack not reaching 

required voltage; or charger 

output reduced due to high 

temperatures.

Check connections, that battery type matches 

selected charge profile and operate the charger at 

a lower ambient temperature. Reset the charger by 

interrupting AC power for 15+ seconds.

Battery could not be trickle 

charged up to minimum voltage.

Check for shorted or damaged cells. Reset the char-

ger by interrupting AC power for 15+ seconds.

Charger shutdown due to high 

internal temperature.

Ensure sufficient cooling airflow. Reset the charger 

by interrupting AC power for 15+ seconds.

Internal charger fault

Reset the charger by interrupting AC power for 15+ 

seconds. Return to service depot if fault persists.

2

www.delta-q.com

Note: This is a Class A product complying with United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 15. In a domestic 
environment this product may cause radio interference, in which case the user may be required to take adequate measures.

WARNING: Charger connectors must be mated to connectors from the same manufacturer. Failure to do so may void warranty and cause a hazardous condition 
or equipment damage.

Maintenance Instructions

1. 

Do not expose charger to high pressure water spray when cleaning vehicle.

2. 

The enclosure of the charger meets IP66, making it dust-tight and protected against powerful water jets.  The AC 

connection is rated to IP20, which is not protected against water.  Protect the AC connection if used in wet or dusty 

environments.

3. 

If the detachable input power supply cord set is damaged, replace with a cord that is appropriate for your region:

 

­

This charger is provided with a cord set for connection to outlets operating at nominal 120 Volts (or 240 Volts 

as appropriate). If the input plug does not fit the power outlet, contact Delta-Q Technologies for the proper 

cord set terminating in an attachment plug of the proper configuration for the power outlet.

 

­

‘North America: UL or CSA listed / approved detachable cord, 3 conductor, 16AWG minimum and rated SJT; 

terminated in a grounding type IEC 60320 C14 plug rated 250V, 13A minimum

 

­

For all other regions: Safety approved detachable cord, 3 conductor, 1.5mm² minimum, rated appropriately for 

industrial use. The cord set must be terminated on one end with a grounding type input connector appropriate 

for use in the country of destination and, on the other end, an output grounding type IEC 60320 C14 plug.

LED Colour

Indication

Green

 

­

If solid: Charging complete and maintenance mode is active.

 

­

If flashing:

Short: <80% Charge.
Long:  >80% Charge.
When battery is not connected: Charge Profile (Algorithm Number) is 
displayed when first connected to AC, then will show “Battery low voltage” 
error

Amber

 

­

If flashing: Reduced power mode due to high internal charger temperature.

Red

 

­

If flashing: Charging error. Reset charger power and refer to Troubleshooting 
Instructions below.