background image

Selecting A Charge Profile

Delta-Q’s QuiQ 1500 Charger can store up to 10 charging profiles, also called charge algorithms. This section shows how to 

identify the default profile and select a new profile using the “tap method.” 

QuiQ chargers are reprogrammable using the QuiQ Programmer supplied by Delta-Q to its OEM partners. Pre-2006 QuiQ 

chargers with serial number prefix DQCP allow pre-loaded profiles to be selected, but cannot be reprogrammed with new 

profiles.

Figure 2: Remove positive lead from positive 

terminal on the battery pack.

Figure 3: Reconnect AC power to the charger.

Figure 1: Disconnect AC power.

Figure 4: Charger LED indicator self-test.

Figure 7: Touch the positive lead to the positive 

battery terminal for 3 seconds.

Identify the default profile

1. Required supplies include an insulated 

wrench, eye protection and gloves.

2. Disconnect the AC power source from 

the charger, either from the wall outlet, 

or from the IEC320 connector on the 

charger.

3. Use your insulated wrench to remove 

the positive lead from the positive 

terminal on the battery pack.

4. Reconnect AC power.

5. Charger will conduct a self-test of its 

LED indicators.

6a. For 11 seconds after the self-test, the 

charger will display its default charge 

profile. Profiles #1-6 will display on the 

ammeter, as well as on the bulk charge 

indicator.

6b. Charge profiles #7 and above will 

display on the bulk charge indicator. 

If the charge profile number has two 

digits, it will be displayed by one or 

more flashes, a pause, then one or more 

flashes (e.g. #13 =                                       )

Select a new profile

7. Disconnect AC power (see Figure 1).
8. Reconnect AC power (see Figure 3).
9. Touch the positive lead to the positive 

terminal for three seconds (+/- 0.5 

seconds), then remove the lead. You will 

see the next profile displayed on the 

charger’s display. Repeat this step until 

you reach the desired charge profile.

10. When the charger displays the 

desired charge profile, apply the positive 

lead to the positive battery terminal for 

10 seconds. When the charge profile 

is locked, you will hear a click from the 

charger. See Figure 7 for how to apply 

the positive lead to the positive terminal.

11. Disconnect AC power, wait for the 

LED indicator display to turn off, then 

reconnect AC power. (See Figure 3)

12.  Check the LED display to ensure that 

the desired charge profile is selected. 

13. Disconnect the charger from AC 

power and wait for the LED indicator 

display to turn off. (See Figure 1)

14. Reconnect the positive lead to the 

positive battery terminal.

Figure 8: Reattach the positive lead to the 

positive terminal after disconnecting AC power.

Figure 5: Charge profile #1 on the  ammeter.

Figure 6: Bulk charge indicator displays 

charge profiles 7 and above.

Delta-Q QuiQ 1500 Charger Manual

3

Visit www.youtube.com/deltaqtechnologies for instructional videos.