www.deltaregis.com
sales@deltaregis.com
7370 Commercial Circle
Fort Pierce, FL 34951
(
772.465.4302
15
4. Device Visual(lights) & Audible(beep) feedback description
Function
Status
Lights
Beep
(Sound on)
OK
Fastening is
completed properly
Green light ON
(Top)
1 Short beep
OK ALL
Fastening is
completed for entire
workpiece properly
Amber light
ON
(Top)
1 Long beep
NG
Fastening operation
error
Red Light ON
(Top)
Continuous
short beep
until trigger is
released
Limit rotation error
If limit rotation
value is not met
and impact value
has been achieved
(Cross-thread)
Red Light ON
(Top)
Continuous
fast beep
until trigger is
released
Stripped Screw
If device drive
continues to spin
outside of normal
parameters
Red Light ON
(Top)
Continuous
short beep
until trigger is
released
Sleep Mode
If device is unused
for 180 sec, sleep
mode is engaged
None
None
Overcurrent
Protection (A)
SXI-100
SXI-70
20
(Shows on
device display)
None
None
SXI-50
25
(Shows on
device display)
None
None
Low Speed/Stall Protection
Error Detected
Continuous
Red Light ON
3 Consecutive
short beeps
Battery ID Identification Error
Device is disabled
Red/Green
Light flashing
alternatively
Continuous
beep
Low Voltage
Protection
SXI-100
SXI-70
<14.4V Device functions
normally
Red Light ON
(Bottom)
None
SXI-50
<10.8V
Insufficient
Voltage
Protection
SXI-100
SXI-70
<14.4V
Device is disabled
Red Light
Flashes
(Bottom)
Continuous
short beep
until battery
is removed
SXI-50
<10.8V