10
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which
has a 3-prong grounding type plug and a 3-hole receptacle which will accept the tool’s plug. When using an extension
cord, be sure to use one heavy enough to carry the current of the tool. An undersized cord will cause a drop in line
voltage, resulting in loss of power and overheating. Fig. 22 & 23, shows the correct gauge to use depending on the
cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
EXTENSION CORDS
Fig. 22
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS
Ampere Volts Total Length of Gauge of
Rating Cord in Feet Extension Cord
0-6 120 up to 25
18 AWG
0-6
120 25-50 16 AWG
0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120 up to 25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120 up to 25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120 up to 25 14 AWG
12-16 120 25-50 12 AWG
12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS
Ampere Volts Total Length of Gauge of
Rating Cord in Feet Extension Cord
0-6 240 up to 50
18 AWG
0-6
240 50-100 16 AWG
0-6 240 100-200 16 AWG
0-6 240 200-300 14 AWG
6-10 240 up to 50 18 AWG
6-10 240 50-100 16 AWG
6-10 240 100-200 14 AWG
6-10 240 200-300 12 AWG
10-12 240 up to 50 16 AWG
10-12 240 50-100 16 AWG
10-12 240 100-200 14 AWG
10-12 240 200-300 12 AWG
12-16 240 up to 50 14 AWG
12-16 240 50-100 12 AWG
12-16 240
GREATER THAN 100 FEET NOT RECOMMENDED
Fig. 23
OPERATING CONTROLS
FOR OPERATOR SAFETY, BEFORE OPERATING THE MACHINE, MAKE CERTAIN THAT THE DUST INTAKE HOSE IS
ALWAYS ATTACHED TO THE DUST INTAKE PORT. THE ROTATING FAN LOCATED INSIDE THE BLOWER HOUSING IS
ACCESSIBLE THROUGH THE DUST IN-TAKE PORT AND CAN BE HAZARDOUS. ALWAYS WEAR PROPER APPAREL. DO
NOT WEAR JEWELRY AND KEEP FINGERS AND ALL FOREIGN OBJECTS OUT OF THE DUST INTAKE PORT. FOLLOW
THE SAFETY RULES EARLIER IN THIS MANUAL.
Fig. 24
Fig. 25
ON/OFF SWITCH
The on/off switch is located on the side of the motor.
To turn the dust collector
“ON,”
push switch toggle (A)
Fig. 24, toward the “ON” mark. To turn the dust collector
“OFF,”
push switch toggle (A) toward the “OFF” mark.
LOCKING SWITCH IN
THE “OFF” POSITION
When the tool is not in use, the switch should be locked
in the
“OFF”
position to prevent unauthorized use. This
can be done by grasping the switch toggle (A) Fig. 25,
and pulling it out of the switch (B) as shown. With the
switch toggle (A) Fig. 25, removed, the switch will not
operate. However, should the switch toggle (A) be re-
moved while the dust collector is running, it can be
turned
“OFF”
once, but cannot be restarted without
inserting the switch toggle.
A
A
B
Summary of Contents for 50-775
Page 12: ...12 NOTES...