OPERATING CONTROLS

WARNING: BEFORE OPERATING THE MACHINE, FOR OPERATOR SAFETY, ALWAYS MAKE CERTAIN THAT

EACH DUST INTAKE PORT (WHICH IS NOT BEING USED OR PREVIOUSLY ASSEMBLED TO A DUST COLLECTION
SYSTEM) BE COVERED WITH A DUST INTAKE PORT CAP. THE ROTATING FAN INSIDE THE BLOWER HOUSING IS
ACCESSIBLE THROUGH THE DUST INTAKE PORTS AND IS HAZARDOUS. ALWAYS WEAR PROPER APPAREL, DO
NOT WEAR JEWELRY, AND KEEP FINGERS AND ALL FOREIGN OBJECTS OUT OF THE DUST INTAKE PORTS.
FOLLOW THE SAFETY RULES STATED EARLIER ON PAGES 3 AND 4 IN THIS MANUAL.

Fig. 28

Fig. 29

ON/OFF SWITCH

The “on/off” switch is located on the side of the motor.
To turn the dust collector “ON”, push the start button
(A) Fig. 28. To turn the dust collector “OFF”, push stop
button (B).

LOCKING SWITCH
IN THE “OFF” POSITION

IMPORTANT: 

When the machine is not in use, the switch

(A) Fig.18 should be locked in the OFF position using a
padlock (C), with a 3/16" diameter shackle to prevent
unauthorized use.

CIRCUIT BREAKER

Your dust collector motor is supplied with a resettable circuit breaker. If the motor shuts off or fails to start due to an
overload condition, turn the dust collector switch “OFF,” let the motor cool three to five minutes, and push the reset button
(D) Fig. 29, on the circuit breaker to reset the breaker. The motor can then be turned on again in the usual manner. If the
overload continues to trip, take the dust collector to a Delta Authorized Service Center for repair.

MAINTENANCE

NOTE:

Before any maintenance or service is performed, be sure the unit is disconnected from the power source to

prevent starting. All servicing other than the items recommended in this Instruction Manual should be performed by an
authorized service facility. When storing your dust collector, remove power supply cord from the electrical outlet. Coil
the cord neatly and place it off the floor on the base of the dust collector to eliminate potential cord damage.

MOTOR MAINTENANCE

Removing dust and dirt: Blow off motor with low pressure air to remove dust or dirt. Air pressure above 50 P.S.I. should
not be used as high pressure may damage insulation and blow dirt under loosened tape. The operator performing this
cleaning function should always wear eye protective goggles. Dust can cause excessive insulation temperatures.

A

B

A

C

D

Summary of Contents for 50-850

Page 1: ...0 850 PART NO 902115 11 15 02 Copyright 2002 Delta Machinery ESPAÑOL PÁGINA 15 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 800 223 7278 In Canada call 1 800 463 3582 ...

Page 2: ... with padlocks master switches or by removing starter keys 9 DON T FORCE TOOL It will do the job better and be safer at the rate for which it was designed 10 USE RIGHT TOOL Don t force tool or attachment to do a job for which it was not designed 11 WEAR PROPER APPAREL No loose clothing gloves neckties rings bracelets or other jewelry to get caught in moving parts Nonslip footwear is recommended We...

Page 3: ...or plug If the dust collector is not operating properly or has been damaged left outdoors or has been in contact with water take it to an Authorized Service Center for service 14 DO NOT use the dust collector as a toy DO NOT use near or around children 15 DO NOT insert fingers or foreign objects into the dust intake port or discharge port Keep hair loose clothing fingers and all body parts away fr...

Page 4: ...TRATE TECHNIQUE ONLY Fig 2 1 Locking Bands for Filter and Dust Collection Bags 2 2 Filter Bag 3 Dust Collection Bag 4 Filter Bag Support Rod 5 Extension Rod 6 Clamps 2 7 6 Dia Flexible Hose 8 Drum Support 3 9 Casters 3 8 Lockwashers 3 8 16 Hex Nuts 4 10 U Bracket for Filter Bag Support Rod 11 Lower Dust Bag retaining Clips 4 Fig 3 12 Blower and Motor Assembly 13 Clamp 14 4 Dia Flexible Hose 15 Int...

Page 5: ... at the base of blower and motor assembly B Fig 6 with six pre drilled holes C in base A and fasten with six 5 16 18x5 8 hex head screws D and 5 16 lockwashers E 2 Fig 7 illustrates the blower and motor assembly B fastened to base A 3 Assemble drum support F Fig 8 to the two threaded holes in the corner of base A as shown in Fig 8 with two 5 16 18x5 8 hex head screws and 5 16 lockwashers G NOTE Do...

Page 6: ...n the holes in the drum support M Fig 12 with the holes in the drum J Place a 5 16 flat washer on a 5 16 18x5 8 hex head screw then 5 16 lockwasher onto the hex head screw insert the hex head screw thru the hole in drum support and drum Thread a 5 16 hex nut onto the hex head screw and tighten securely Fasten the remaining drum supports to the drum J in the same manner 7 The dust collector is supp...

Page 7: ...CE 2 Align the four holes in dust intake port A Fig 15 with the mounting holes in flange B of blower and motor assembly and fasten with four sheet metal screws C Fig 16 illustrates the dust intake port assembled to the blower assembly 3 NOTE Two dust intake port caps D Fig 17 are supplied with the dust collector The caps are to be placed into the dust intake ports E when the intake ports are not i...

Page 8: ...Position open end of filter bag A Fig 19 over lip of dust drum E Insert locking band F Fig 20 through the loops of filter bag A and fasten with clamp G as shown in Fig 21 NOTE Make certain locking band is positioned in the channel of drum F before fastening clamp 4 Pull up on each retaining clip A Fig 22 and insert the dust collection bag B underneath each retaining clip to hold the dust collectio...

Page 9: ...e tool to the power source make sure the switch is in the OFF position GROUNDING INSTRUCTIONS WARNING THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK This tool must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This tool is equipped with a cord having an ...

Page 10: ...with a 240 volt plug should only be connected to an outlet having the same configuration as the plug illustrated in Fig 26 No adapter is available or should be used with the 240 volt plug AS A PRECAUTION IN ALL CASES MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED IF YOU ARE NOT SURE HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE Fig 27 MINIMUM GAUGE EXTENSION CORD RECOMMENDED SIZE...

Page 11: ...f the motor shuts off or fails to start due to an overload condition turn the dust collector switch OFF let the motor cool three to five minutes and push the reset button D Fig 29 on the circuit breaker to reset the breaker The motor can then be turned on again in the usual manner If the overload continues to trip take the dust collector to a Delta Authorized Service Center for repair MAINTENANCE ...

Page 12: ...elta s sole warranty and sets forth the customer s exclusive remedy with respect to defective products all other warranties express or implied whether of merchantability fitness for purpose or otherwise are expressly disclaimed by Delta Printed in U S A PARTS SERVICE OR WARRANTY ASSISTANCE All Delta Machines and accessories are manufactured to high quality standards and are serviced by a network o...

Page 13: ...hern Avenue Suite 105 Phone 602 437 1200 Fax 602 437 2200 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390 5555 Fax 909 390 5554 San Leandro 94577 Oakland 3039 Teagarden Street Phone 510 357 9762 Fax 510 357 7939 COLORADO Arvada 80003 Denver 8175 Sheridan Blvd Unit S Phone 303 487 1809 Fax 303 487 1868 FLORIDA Davie 33314 Miami 4343 South State Rd 7 441 Unit 107 Phone 954 ...