The AG812 is to be located on a 

solid, non-combustible surface

, such as concrete. Mark the 

Gate  location  from  the  architect’s  drawings.  Conduit  for  the  Gate  motor  and  controls  must  be 
brought  to  the  stub-up  area  within the Gate’s bottom opening (shown above). Foundation bolt 
location can be marked from the Gate itself or from a template (Delta P/N D03180). 
 
1. 

Remove cardboard flanges of carton from wooden pallet. Lift carton clear of the AG812 
Gate. Do not cut through carton while on the Gate; the knife may score the Gate finish! 

 
2. 

Insert the key in the lick, unlock and remove cabinet door. 

 
3. 

Remove bolts holding cabinet to the shipping pallet. 

 
4. 

Temporarily  set  Gate  where  indicated  on  site  plans,  transfer  mounting  hole  location  to 
foundation (or use template). Set Gate aside. 

 
5. 

Use  a  masonry  drill  to  provide  the  holes  for  the  mounting  bolts  (4  –  3/8”  X  4”  long).  If 
appropriate for your application use lag shields (not provided). 

 
6. 

Relocate the Gate and install the lag bolts using a flat and lock washer on each. 

 
7. 

Locate gearbox breather vent and remove plug. Vent hole faces upwards when the box 
is in operation. 

 
8. 

Install Gate Arm. 

 

Wiring 

 
As  indicated  above,  the  Gate  will  function  using  a  wide  variety  of  control  inputs.  Consult  the 
architectural  plans  for  the  required  control  functions,  and  then  refer  to  the  specific  Delta 
Scientific Application Guide that covers that function. Common to all hookups: 
 
1. 

Standard  Power  input  is  120/1/60  VAC  for  Gate  Motor  and  control  power.  The  AG812 
may be ordered from the factory equipped to operate at 240/1/50 also. Conduit should 
be run from below grade to the center stub-up area as shown in the installation drawing. 
Field  wiring  connections  are  terminated  at  terminals  L1  (hot)  and  L2  (neutral).  Other 
input voltages are available, and must be selected at time of order. The unit should be 
grounded at the provided terminal (green). 

 
2. 

Gate  Auto-Manual:  With  the  Power  ‘On’,  switching  the  Auto-Manual  switch  to  ‘Manual’ 
will  vend  (raise)  the  Gate.  To  reset  the  Gate,  switch  Auto-Manual  to  ‘Reset’  position 
momentarily. 

 
3. 

Heater  On-Off  –Auto:  Gate  may  be  optionally  supplied  with  a  60  watt  heater  to  guard 
against  condensation  on  the  gate  interior  surfaces  and  to  provide  some  heating  to 
reduce gear box lube oil viscosity in extreme cold. We suggest that the heater switch be 
placed in the ‘Auto’ position at all times. 

Summary of Contents for AG812

Page 1: ...ODEL AG812 ACCESS GATE WARRANTY INSTALLATION OPERATION CORPORATE HEADQUARTERS 40355 Delta Lane Palmdale California 93551 Phone 661 575 1100 Fax 661 575 1109 Email info deltascientific com EASTERN REGI...

Page 2: ...ISCLAIMER Please note careful consideration must be devoted to the selection placement and design of a Barricade installation Just as in the case of any Barricade system perimeter security device or s...

Page 3: ...MANUAL GATE ARM OPERATION OPTION 6 DRIVE BELT TENSION 6 SPARE PARTS ORDER DATA 7 DART ARM OPTION 7 HOOK UP SCHEMATICS 2 Lane Single Direction Cash In Or Out 8 2 Lane Cash Entry Free Exit 9 1 Lane Coi...

Page 4: ...These devices may be used independently or in combination In short any device which can provide a contact closure may be used to vend or reset the Gate Safety The Model AG812 Access Gate is equipped w...

Page 5: ...ox breather vent and remove plug Vent hole faces upwards when the box is in operation 8 Install Gate Arm Wiring As indicated above the Gate will function using a wide variety of control inputs Consult...

Page 6: ...loosen the thumbscrew on the up limit switch cam and rotate slightly CCW Confirm as above 4 To adjust the gate arm for less upward travel loosen the thumbscrew on the up limit switch cam and rotate s...

Page 7: ...c For control circuits list model number serial number S N drawing number and customer number taken from the nameplate on the controller Dart Arm optional The dart arm is an optional factory installed...

Page 8: ...Copyright 2013 Delta Scientific Corporation Page 8 of 17 All Rights Reserved Document A2021 6...

Page 9: ...Copyright 2013 Delta Scientific Corporation Page 9 of 17 All Rights Reserved Document A2021 6...

Page 10: ...Copyright 2013 Delta Scientific Corporation Page 10 of 17 All Rights Reserved Document A2021 6...

Page 11: ...Copyright 2013 Delta Scientific Corporation Page 11 of 17 All Rights Reserved Document A2021 6...

Page 12: ...Copyright 2013 Delta Scientific Corporation Page 12 of 17 All Rights Reserved Document A2021 6...

Page 13: ...Copyright 2013 Delta Scientific Corporation Page 13 of 17 All Rights Reserved Document A2021 6...

Page 14: ...Copyright 2013 Delta Scientific Corporation Page 14 of 17 All Rights Reserved Document A2021 6...

Page 15: ...ly by draining old oil and refilling with clean Texaco Vanguard oil or equivalent 2 Tighten all nuts bolts and screws on the Gate assembly every 60 days or as necessary 3 Wash and wax the Gate cabinet...

Page 16: ...e belt tension to be checked Open the AG812 s door and inspect the drive belt for looseness or excessive wear If the belt appears worn or frayed or if the belt appears loose first remove Electrical Po...

Page 17: ...T ASSEMBLY 4369 11 BEARING PLATE with BUSHING FOR AG812 4369 12 SHAFT COLLAR 1 25 BORE 4369 13 ARM HOLDER 4369 14 ARM HOLDER RETAINING PLATE 4369 15 CONNECTING ARM with BUSHING 4369 16 GEAR BOX MOUNTI...

Page 18: ......

Page 19: ...PLATE 4369 14 15 1 CONNECTING ARM WITH BUSHINGS 4369 15 15A 1 DART CONNECTING ARM ASSY OPTION 5 7 5 7 3312 00 16 1 GEAR BOX MOUNTING PLATE 4369 16 17 1 MOTOR MOUNTING PLATE 4369 17 18 2 LIMIT SWITCH...

Page 20: ...F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MODEL C 24 B1 BRIDGE DIODE 1A 50V DIGI KEY DB 101NP C1 CAPACITOR 1000 mF 35V C2 CAPACITOR 330 mF...

Page 21: ......

Page 22: ...R 330 OHM 1 2W U1 U2 OPTO ISOLATOR MOTOROLA MOC3041 CA CAMDEN TERMINAL STRIP FEMALE CTB 7300 24F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MO...

Page 23: ......

Reviews:

Related manuals for AG812