Chapter 6 Control Modes of Operation
6-16
Revision June 2010
Relevant parameters:
P1 - 06
SFLT
Accel / Decel Smooth Constant of
Analog Speed Command (Low-pass
Filter)
Communication Addr.:
010CH
,
010DH
Default: 0
Related Section:
Applicable Control Mode: S
Section 6.3.3
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display Format: DEC
NOTE
1)
If the setting value of parameter P1-06 is set to 0, it indicates the function of this
parameter is disabled and the command is just By-Pass.
SFLT
Target Speed
6.3.4 Analog Speed Input Scaling
The analog voltage between
V_REF and GND
determines the motor speed command.
Using with parameter P1-40 (Max. Analog Speed Command) can adjust the speed control
ramp and its range.
5
10
-5
-10
3000rpm
5000rpm
-3000rpm
-5000rpm
Analog Input Voltage (V)
The speed control ramp is
determined by parameter P1-40
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...