Chapter 7 Servo Parameters
Revision June 2010
7-43
Group 2: P2-xx Extension Parameters
P2 - 00
KPP
Proportional Position Loop Gain
Address: 0200H, 0201H
Default: 35
Related Section:
Applicable Control Mode: PT
Section 6.2.8
Unit: rad/s
Range: 0 ~ 2047
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the position loop gain. It can increase stiffness,
expedite position loop response and reduce position error. However, if the setting
value is over high, it may generate vibration or noise.
P2 - 01
PPR
Position Loop Gain Switching Rate
Address: 0202H, 0203H
Default: 100
Related Section:
Applicable Control Mode: PT
Section 6.2.8
Unit: %
Range: 10 ~ 500
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the position gain switching rate when the gain
switching condition is satisfied. Please refer to P2-27 for gain switching control
selection settings and refer to P2-29 for gain switching condition settings.
P2 - 02
PFG
Position Feed Forward Gain
Address: 0204H, 0205H
Default: 50
Related Section:
Applicable Control Mode: PT
Section 6.2.8
Unit: %
Range: 0 ~ 100
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the feed forward gain when executing position
control command. When using position smooth command, increase gain can
improve position track deviation. When not using position smooth command,
decrease gain can improve the resonance condition of mechanical system.
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...