Chapter 7 Servo Parameters
7-62
Revision June 2010
P2 - 50
DCLR
Pulse Deviation Clear Mode
Address: 0264H, 0265H
Default: 0
Related Section: N/A
Applicable Control Mode: PT
Unit: N/A
Range: 0 ~ 2
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
For digital input function (DI function), please refer to Table 7.A.
This pulse deviation clear function is enabled when a digital input is set to pulse
clear function (CCLR mode, DI (Digital Input) setting value is 0x04). When this
input is triggered, the position accumulated pulse number will be clear to 0.
(available in PT mode only)
0: CCLR is triggered by rising-edge
1: CCLR is triggered bu level
P2 - 51
Reserved (Do Not Use)
P2 - 52
Reserved (Do Not Use)
P2 - 53
KPI
Position Integral Compensation
Address: 026AH, 026BH
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 6.3.6
Unit: rad/s
Range: 0 ~ 1023
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the integral time of position loop. When the value of
position integral compensation is increased, it can decrease the position control
deviation. However, if the setting value is over high, it may generate position
overshoot or noise.
P2 - 54
Reserved (Do Not Use)
P2 - 55
Reserved (Do Not Use)
P2 - 56
Reserved (Do Not Use)
P2 - 57
Reserved (Do Not Use)
P2 - 58
Reserved (Do Not Use)
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...