Chapter 7 Servo Parameters
7-76
Revision June 2010
2. DI Signal Control
Set the value of DI signal as JOGU and JOGD (refer to Table 8.A).
Users can perform JOG run forward and run reverse control.
3. Communication Control
To perform a JOG Operation via communication command, use communication
addresses 040AH and 040BH.
(1) Enter 1 ~ 5000 for the desired JOG speed
(2) Enter 4998 to JOG in the P(CCW) direction
(3) Enter 4999 to JOG in the N(CW) direction
(4) Enter 0 to stop the JOG operation
Please note that when using communication control, please set P2-30 to 5 to
avoid that there are excessive writes to the system flash memory.
P4 - 06
▲ ■
FOT
Force Output Contact Control
Address: 040CH, 040DH
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 4.4.3
Unit: N/A
Range: 0 ~ 0xFF
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
The function of Digital Outout (DO) is determined by the DO setting value. The
user can set DO setting value (0x30 ~ 0x3F) via communication and then write the
values into P4-06 to complete the settings.
Bit00 corresponds with DO setting value 0x30
Bit01 corresponds with DO setting value 0x31
Bit02 corresponds with DO setting value 0x32
Bit03 corresponds with DO setting value 0x33
Bit04 corresponds with DO setting value 0x34
Bit05 corresponds with DO setting value 0x35
Bit06 corresponds with DO setting value 0x36
Bit07 corresponds with DO setting value 0x37
Bit08 corresponds with DO setting value 0x38
Bit09 corresponds with DO setting value 0x39
Bit10 corresponds with DO setting value 0x3A
Bit11 corresponds with DO setting value 0x3B
Bit12 corresponds with DO setting value 0x3C
Bit13 corresponds with DO setting value 0x3D
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...