background image

MODELS:  SLM100/SLM80

Page 4.

SPECIFICATIONS 

Note: Design and sp

tions subject to change without notice.

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY

Delta Electronics Inc. (“Delta Electronics”) warrants to the 

original consumer purchaser in the USA and Canada that the 

Breez ventilation fan products will be free from defects in 

material or workmanship. This warranty is limited to three 

(3) years from the original date of purchase.
Limitations and Exclusions

1. During the warranty period, a replacement for any 

defective product will be supplied free of charge for 

installation by the consumer. The warranty provided 

herein does not cover charges for labor or other costs 

incurred in the troubleshooting, repair, removal, and 

installation service. 

2. All returns of defective parts or products must include the 

product model number, and must be made through an 

authorized Delta Electronics distributor. Authorized 

returns must be shipped prepaid. Repaired or replacement 

products will be shipped by Delta Electronics F.O.B. 

shipping point. 

3. Delta Electronics shall not be liable for any indirect, 

incidental, consequential, punitive, or special damages 

arising out of or in connection with products use or 

performance, regardless of the form of action whether in 

contract, tort (including negligence), strict product liability 

or otherwise. 

4. This warranty does not extend to fluorescent lamp starters 

and tubes. 

5. The warranty does not cover if user does not comply with 

manufacture’s installation manual. 

6. To qualify for warranty service, you must notify Delta 

Electronics at the address or telephone number below.

7. Delta Electronics shall have no liability to the original 

owner-user with respect to any defect caused by abuse, 

misuse, neglect, improper transportation or storage, 

improper testing, improper installation, improper 

operation, improper use, improper maintenance, 

improper repair, improper alteration, improper 

modification, tampering or accident of products or parts 

thereof, or unusual deterioration or degradation of 

products or parts thereof due to a physical environment 

beyond the requirements of products’ specifications.  

Address: 46101 Fremont Boulevard, Fremont, CA 94538  

US Toll Free Number: 

1-888-979-9889 - Technical Support

1-877-685-4384 - Customer Sales Support

Model 

No.

Voltage

(V) 

Frequency

(Hz) 

Power 

@ 0.1SP 

(W)

Air Flow 

@ 0.1SP 

(CFM) 

Power

(W) 

Weight 

(lb.) 

SLM80

120 

60

8.5

80 

13 

6.6

SLM100

120 

60 

14.5 

100 

20 

6.6 

DIMENSIONS

OPERATION 

Turn on the power switch to operate ON and LED indicator is

green. 

MAINTENANCE

 

WARNING: 

Disconnect

 

power source before working on unit.  Routine 

maintenance must be done every year. 

CAUTION: 

1.

Never use gasoline, benzene, thinner or any other 

 such chemicals for cleaning the ventilating fan. 

2.

Do not allow water to enter motor. 

3.

Do not soak resin parts in water over 

140°F (60°C)

.

CLEANING

1.

Pull down the spring to remove grille.

2.

Wash and clean grille. (Use non-abrasive kitchen detergent, 
wipe dry with new cloth.) 

3.

Using a cloth dampened with non-abrasive kitchen 

detergent, remove dust and dirt from ventilating fan. Wipe 

dry with new cloth. 

4.

Replace grille.

Slots

Grille

Spring

 

TEST RUN & GRILLE ATTACHMENT 

1.

When the power on, check for abnormal vibration or sound.

2.  Insert  the  mounting  springs  into  the  slots  and  mount  the

grille to the fan unit. 

4.

Push all wires into wiring compartment of unit and replace

wiring cover.

WARRANTY 

11 ¼” 

10 ½”

13”

13”

”3

1

 ”

¼ 1

1

3 ⁄”

⁄

4”

3.

approved wire nuts (not provided) to connect house

branch-circuit wires with ventilating fan-housing wires. Connect 

wires as shown in wiring diagrams. 14 AWG (2.1 mm ) is the 

smallest conductor that shall be used for branch-circuit wiring.

 

JUNCTION BOX

BLACK

WHITE

OFF

ON

POWER SWITCH

GREEN

L

N

SWITCH BOX

GRD

Summary of Contents for breez Slim SLM100

Page 1: ...and standards 4 nt air is needed for proper combustion and exhausting of gases through ue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local ...

Page 2: ...h flange Screw M4x6 mm 1 Suspension Bracket 1 Joist Tabs Roof cap with built in damper Seal gap around housing Caulk termination to duct Fan housing Short piece of flexible duct helps alignment and absorbs sound or Wall cap damper Wall cap 2 3 ft straight run before elbow with built in 1 To bend the housing tabs out to 90 degree and make housing tabs contact the bottom or front of the joist 2 The ...

Page 3: ...cure fan body 1 Joist Joist Bottom Of Joist Ceiling Screw Ø4x25 mm Screw Ø4x25 mm Wall DUCT CONNECTION 1 Insert the duct into the duct connector and tape all ductworks connection to make them secure and air tight 2 Install the duct with a gradient 1 2 to the outside Inside Outside Duct Body Gradient 1 2 Grille Tape Ceiling Duct Connector Connection method for 3 round duct connector 3 4 oval to 3 r...

Page 4: ...transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications Address 46101 Fremont B...

Reviews: