Chapter 11 Description of Parameter Settings
|
C200 Series
11-58
10
5
1
2 3 4
6 7 8 9
V
60Hz
10
6
1
2
3
4
5
7
9 8
-V
60Hz
F requency
Pr.03-07~03-09 (Positive/Negative Bias Mode)
Pr.03-10 (
Analog F requency Command for
R everse Run)
0: Negative frequency is not valid.
F orward and reverse run is controlled
by digital keypad or external terminal.
1: Neagtive frequency is valid. Positive
frequency = forward run; negative
frequency = reverse run. Direction
can not be sw itched by digital keypad or
external teriminal control.
0: No bias
1:
2: Greater than or equal to bias
3: T he absolute value of the bias voltage
while serving as the center
4: Serve bias as the center
Lower than or equal to bias
Pr.03-05
Analog Positive Voltage Input Bias (AUI) = 10%
Pr.03-14 Analog Negative Input Gain (AUI)= 100%
Pr.00-13 Analog Positive Input Gain (AUI)= 100%
Pr.00-21=0 (Digital keypad control and run in F WD direction)
10
5
1
2 3 4
6 7 8 9
V
60Hz
10
6
1
2
3
4
5
7
9 8
-V
60Hz
54Hz
Pr.03-07~03-09 (Positive/Negative Bias Mode)
Pr.03-10 (
Analog F requency Command for
Reverse Run)
0: Negative frequency is not valid.
F orward and reverse run is controlled
by digital keypad or external terminal.
1: Neagtive frequency is valid. Positive
frequency = forward run; negative
frequency = reverse run. Direction
can not be switched by digital keypad or
external teriminal control.
0: No bias
1:
2: Greater than or equal to bias
3: T he absolute value of the bias voltage
while serving as the center
4: Serve bias as the center
Lower than or equal to bias
F requency
Pr.03-05
Analog Positive Voltage Input Bias (AUI) = 10%
Pr.03-14 Analog N egative Input Gain (AUI)= 100%
Pr.00-13 Analog Positive Input Gain (AUI)= 100%
Pr.00-21=0 (D igital keypad control and run in F WD direction)
10
5
1
2 3 4
6 7 8 9
V
60Hz
10
6
1
2
3
4
5
7
9 8
-V
60Hz
54Hz
Pr.03-07~03-09 (Positive/N egative Bias Mode)
Pr.03-10 (
Analog F requency Command for
R everse Run)
0: Negative frequency is not valid.
F orward and reverse run is controlled
by digital keypad or external terminal.
1: Neagtive frequency is valid. Positive
frequency = forward run; negative
frequency = reverse run. Direction
can not be sw itched by digital keypad or
external teriminal control.
0: No bias
1:
2: Greater than or equal to bias
3: T he absolute value of the bias voltage
while serving as the center
4: Serve bias as the center
Lower than or equal to bias
F requency
Pr.00-21=0 (Digital keypad control and run in F WD direction)
Pr.03-05
Analog Positive Voltage Input Bias (AUI) = 10%
Pr.03-14 Analog Negative Input Gain (AUI)= 100%
Pr.00-13 Analog Positive Input Gain (AUI)= 100%
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com