Chapter 11 Description of Parameter Settings
|
C200 Series
11-63
loss of the ACI signal is recovered or drive is stop.
Multi-function Output 1 (AFM1)
Factory Setting: 0
Multi-function Output 2 (AFM2)
Factory Setting: 0
Settings 0~23
Function Chart
Settings
Functions
Descriptions
0
Output frequency (Hz)
Max. frequency Pr.01-00 is regarded as 100%.
1
Frequency command (Hz)
Max. frequency Pr.01-00 is regarded as 100%.
2
Motor speed (Hz)
600Hz is regarded as 100%
3
Output current (rms)
(2.5 X rated current) is regarded as 100%
4
Output voltage
(2 X rated voltage) is regarded as 100%
5
DC Bus Voltage
450V (900V)=100%
6 Power
factor
-1.000~1.000=100%
7
Power
Rated power is regarded as 100%
8
Output torque
Full-load torque is regarded as 100%
9 AVI
0~10V=0~100%
10 ACI
0~20mA=0~100%
11 AUI
-10~10V=0~100%
12
q-axis current (Iq)
(2.5 X rated current) is regarded as 100%
13
q-axis feedback value (Iq)
(2.5 X rated current) is regarded as 100%
14
d-axis current (Id)
(2.5 X rated current) is regarded as 100%
15
d-axis feedback value (Id)
(2.5 X rated current) is regarded as 100%
16
q-axis voltage (Vq)
250V (500V) =100%
17
d-axis voltage(Vd)
250V (500V) =100%
18
Torque command
Rated torque is regarded as 100%
19 Reserved
20
Output for CANopen control
For CANopen analog output
21 RS485
analog
output
For communication output (CMC-MOD01, CMC-EIP01,
CMC-PN01, CMC-DN01)
22
Reserved
23 Constant
voltage/current
output
Pr.03-32 and Pr.03-33 controls voltage/current output
level
0~100% of Pr.03-32 corresponds to 0~10V of AFM1.
Gain of Analog Output 1 (AFM1)
Factory Setting: 100.0
Gain of Analog Output 2 (AFM2)
Factory Setting: 100.0
Settings 0~200.0%