Chapter 11 Description of Parameter Settings
|
C200 Series
11-85
1: Standard motor
2: Disable
It is used to prevent self-cooled motor overheats under low speed. User can use electronic thermal
relay to limit driver’s output power.
Electronic Thermal Characteristic for Motor 1
Electronic Thermal Characteristic for Motor 2
Factory Setting: 60.0
Settings 30.0~600.0 sec
The parameter is set by the 150% of motor rated current and the setting of Pr.06-14 and Pr.06-28 to
prevent the motor damaged from overheating. When it reaches the setting, it will display
“EoL1/EoL2” and the motor will be in free running.
1
2
3
4
5
0 20 40 60 80100120140160180200
Operation
time(min)
Load
factor (%)
60Hz or more
50Hz
10Hz
5Hz
Heat Sink Over-heat (OH) Warning
Factory Setting: 85.0
Settings 0.0~110.0
℃
Pr.06-15 sets the heat sink temperature level of the drive. The drive will output an overheating
warning when the temperature exceeds the setting of Pr.06-15. If the setting of Pr.06-15 is higher
than the default setting of the drive, the drive will use the default setting level for warning output.
Capacitor (CAP) overheating level is set by the drive’s default setting, it can not be adjusted.
Over-heating Level (
℃
)
Over-heating Level (
℃
)
Model
IGBT OH1 CAP OH 2
Model
IGBT OH1
CAP OH 2
VFD004CB21A-20
100 95
VFD022CB23A-20 100
95
VFD007CB21A-20
100 95
VFD037CB23A-20 100
95
VFD004CB23A-20
100 95
VFD022CB43A-20 100
95
VFD007CB23A-20
100 95
VFD037CB43A-20 100
100
VFD007CB43A-20
100 95
VFD015CB21A-21M
100 95
VFD015CB43A-20
100 95
VFD022CB21A-21M
100 95
VFD015CB23A-20
100 95
VFD022CB23A-21M
100 95
VFD004CB21A-21M
100 95
VFD037CB23A-21M
100 95
VFD007CB21A-21M
100 95
VFD022CB43A-21M
100 95
VFD007CB23A-21M
100 95
VFD037CB43A-21M
100 100
VFD004CB43A-21M
100 95
VFD040CB43A-20 100
90
VFD007CB43A-21M
100 95
VFD055CB43A-20 100
90
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com