Chapter 11 Description of Parameter Settings
|
C200 Series
11-92
Factory Setting: Read only
Settings 0.0~6553.5V
When malfunction occurs, user can check the current DC voltage. If it happens again, it will
overwrite the previous record.
Output Current at Malfunction
Factory Setting: Read only
Settings 0.00~655.35Amp
When malfunction occurs, user can check the current output current. If it happens again, it will
overwrite the previous record.
IGBT Temperature at Malfunction
Factory Setting: Read only
Settings 0.0~6553.5
℃
When malfunction occurs, user can check the current IGBT temperature. If it happens again, it will
overwrite the previous record.
Capacitance Temperature at Malfunction
Factory Setting: Read only
Settings 0.0~6553.5
℃
When malfunction occurs, user can check the current capacitance temperature. If it happens again,
it will overwrite the previous record.
Motor Speed in rpm at Malfunction
Factory Setting: Read only
Settings 0.0~6553.5
℃
When malfunction occurs, user can check the current motor speed in rpm. If it happens again, it will
overwrite the previous record.
Torque Command at Malfunction
Factory Setting: Read only
Settings 0~65535
When malfunction occurs, user can check the current torque command. If it happens again, it will
overwrite the previous record.
Status of Multi-function Input Terminal at Malfunction
Factory Setting: Read only
Settings 0000h~FFFFh
Status of Multi-function Output Terminal at Malfunction
Factory Setting: Read only
Settings 0000h~FFFFh
When malfunction occurs, user can check the status of multi-function input/output terminals. If it
happens again, it will overwrite the previous record.