Chapter 11 Description of Parameter Settings
|
C200 Series
11-98
It will be recorded as the following table:
First fault
Pr.06-17
ovA
Pr.06-63
3000 ovA occurs at the 3000 min
after operating.
Second fault
Pr.06-17
ovd
Pr.06-63
3482
3482-3000=482 min
ovd occurs at 482 min after
last fault (ovA)
Pr.06-18
ovA
Pr.06-64
3000
Third fault
Pr.06-17
ovA
Pr.06-63
4051
4051-3482=569 min
ovA occurs at 569 min after
last fault (ovd)
Pr.06-18
ovd
Pr.06-64
3482
Pr.06-19
ovA
Pr.06-65
3000
Seven fault
Pr.06-17
ocS
Pr.06-63
12
(12-5824)+64800=58988 min
ocS occurs at 58988 min after
last fault (ocA)
Pr.06-18
ocA
Pr.06-64
5824
Pr.06-19
ocA
Pr.06-65
5003
Pr.06-20
ovA
Pr.06-66
4051
Pr.06-21
ovd
Pr.06-67
3482
Pr.06-22
ovA
Pr.06-68
3000
Time interval between errors occur (day)
Factory Setting: Read only
Settings Read only
Time interval between errors occur (minute)
Factory Setting: Read only
Settings Read only
Low Current Setting Level
Factory Setting: 0.0
Settings 0.0 ~ 6553.5 %
Low Current Detection Time
Factory Setting: 0.00
Settings 0.00 ~ 655.35 sec
Treatment for low current
Factory Setting: 0