Chapter 11 Description of Parameter Settings
|
C200 Series
11-143
Po sitive
to rque
Negative
torque
speed
06-1 2 current limit
06-1 2 current limit
06-1 2 current limit
06-12 current limit
Reverse motor mode
Forward mo tor mode
Forward motor mo de
Reverse motor mode
The level o f torque limit will b e
th e min. va lu e of fo llowing thre e values
Exte rnal analo g termin als
Pr.03-00~02
7: positive torque limit
10: positive/negative torque limit
9: regen erative torque limit
E xternal analog terminals
P r.03-00 ~02
7: po sitive torque limit
10: positive/ne gative torque limit
External ana log termin als
Pr.03-00~03-0 2
8: nega tive to rque limit
10: positive/n egative torque limit
E xternal analog terminals
Pr.03-00~03-02
8: ne gative torque limit
10: positive/ne gative torque limit
Pr.11-19
Reverse rege nerative
to rque limit
Pr.11-17
Forwa rd moto r
torque limit
Pr.11-18
Forward re genera tive
torque limit
Pr.11-20
Reverse motor
to rque limit
Quadrant I
Quadrant II
Quadrant III Quadrant IV
speed
Gain Value of Flux Weakening Curve for Motor 1
Factory Setting: 90
Settings 0~200%
Gain Value of Flux Weakening Curve for Motor 2
Factory Setting: 90
Settings 0~200%
Pr.11-21 and 11-22 are used to adjust the output voltage of flux weakening curve.
For the spindle application, the adjustment method is
1. It is used to adjust the output voltage when exceeding rated frequency.
2. Monitor the output voltage
3. Adjust Pr.11-21 (motor 1) or Pr.11-22 (motor 2) setting to make the output voltage reach motor
rated voltage.
4. The larger number it is set, the larger output voltage you will get.