Chapter 12 Warning Codes
|
C200 Series
12-8
Display on
KPE-LE02
Display on
KPC-CC01
Descriptions
Hd1
Oc HW error
Fault
OC hardware error
Corrective Actions:
Re-power on to try it. If fault code is still displayed on the keypad, please
return to the factory.
Hd2
Ov HW error
Fault
OV hardware error
Corrective Actions:
Re-power on to try it. If fault code is still displayed on the keypad, please
return to the factory.
Hd3
occ HW error
Fault
Occ hardware error
Corrective Actions:
Reboots the power. If fault code is still displayed on the keypad please
return to the factory
AUE
Auto tuning err
Fault
Auto tuning error
Corrective Actions:
1. Check cabling between drive and motor
2. Check the motor capacity and parameters settings
3. Retry
again
AFE
PID Fbk error
Fault
PID loss (ACI)
Corrective Actions:
1. Check the wiring of the PID feedback
2. Check the PID parameters settings
PGF1
PG Fbk error
Fault
PG feedback error
Corrective Actions:
Check if Pr.10-01 is not set to 0 when it is PG feedback control
PGF2
PG Fbk loss
Fault
PG feedback loss
Corrective Actions:
Check the wiring of the PG feedback
PGF3
PG Fbk over SPD
Fault
PG feedback stall
Corrective Actions:
1. Check the wiring of the PG feedback
2. Check if the setting of PI gain and deceleration is suitable
3. Return to the factory
PGF4
PG Fbk deviate
Fault
PG slip error
Corrective Actions:
1. Check the wiring of the PG feedback
2. Check if the setting of PI gain and deceleration is suitable
3. Return to the factory
PGr1
PG Ref error
Fault
Pulse input error
Corrective Actions:
1. Check the pulse wiring
2. Return to the factory
PGr2
PG Ref loss
Fault
Pulse input loss
Corrective Actions:
1. Check the pulse wiring
2. Return to the factory