Chapter 13 CANopen Overview
|
C200 Series
13-14
Index
Sub
Definition
Factory Setting
R/W
Size
Note
3 Inhibit time
0 RW
U16
Unit: 100us
The setting value should be in a
multiple of 10 (integer)
4 CMS-Priority Group
3 RW
U8
5 Event timer
0 RW
U16
Unit: 1ms
0 Number
5
R U8
1 COB-ID used by PDO
80Node-ID RW
U32
00: Acyclic & Synchronous
01~240:Cyclic & Synchronous
2 Transmission Type
5 RW
U8
255:Asynchronous
3 Inhibit time
0 RW
U16
Unit: 100us
The setting value should be in a
multiple of 10 (integer)
4 CMS-Priority Group
3 RW
U8
1801H
5 Event timer
0 RW
U16
Unit: 1ms
0 Number
5
R U8
1 COB-ID used by PDO
80Node-ID RW
U32
00: Acyclic & Synchronous
01~240:Cyclic & Synchronous
2 Transmission Type
5 RW
U8
255:Asynchronous
3 Inhibit time
0 RW
U16
Unit: 100us
The setting value should be in a
multiple of 10 (integer)
4 CMS-Priority Group
3 RW
U8
1802H
5 Event timer
0 RW
U16
Unit: 1ms
0 Number
5
R U8
1 COB-ID used by PDO
80Node-ID RW
U32
00: Acyclic & Synchronous
01~240:Cyclic & Synchronous
2 Transmission Type
5 RW
U8
255:Asynchronous
3 Inhibit time
0 RW
U16
Unit: 100us
The setting value should be in a
multiple of 10 (integer)
4 CMS-Priority Group
3 RW
U8
1803H
5 Event timer
0 RW
U16
Unit: 1ms
0 Number
2 RW
U8
1 1.Mapped Object
60410010H RW
U32
2 2.Mapped Object
60430010H RW
U32
3 3.Mapped Object
0 RW
U32
1A00H
4 4.Mapped Object
0 RW
U32
0 Number
4 RW
U8
1 1.Mapped Object
20260110H RW
U32
2 2.Mapped Object
20266110H RW
U32
1A01H
3 3.Mapped Object
20266210H RW
U32
Call 1(800)985-6929 for Sales