Chapter 13 CANopen Overview
|
C200 Series
13-16
Index Sub
Definition
Factory
Setting
R/W Size
Note
Bit1 1
:
Reset
Bit2~15 Reserved
0 Number
DH
R U8
2021H
1 Error
code
0
R U16
2 AC motor drive status
0
R
U16
Bit 0~1 00B
:
stop
01B
:
decelerate to stop
10B
:
waiting for operation
command
11B
:
in operation
Bit
2
1
:
JOG command
Bit
3~4
00B
:
forward running
01B
:
switch from reverse
running to forward running
10B
:
switch from forward
running to reverse running
11B
:
reverse running
Bit
5~7
reserved
Bit 8
1
:
master frequency command
controlled by communication
interface
Bit 9
1
:
master frequency command
controlled by analog signal
input
Bit 10
1
:
operation command
controlled by communication
interface
Bit
11~15
Reserved
3
Frequency
command
(
F
)
0 R
U16
4
Output
frequency
(
H
)
0
R
U16
5
Output
current
(
AXX.X
)
0 R
U16
6
DC-BUS
voltage
0 R
U16
7
output
voltage
0 R
U16
8
The segment currently
executed by multi-segment
speed command
0 R
U16
9
Display
output
current
(
A
)
0 R
U16
A
Display
counter
value
(
c
)
0 R
U16
B
Display actual output
frequency (H)
0 R
U16
C Display DC-BUS voltage (u)
0
R
U16
D Display output voltage (E)
0
R
U16
E
Display output power angle
(n)
0 R
U16
F
Display output power in kW
(P)
0 R
U16
10
Display actual motor speed
in rpm (r)
0 R
U16
11
Display estimate output
torque % (t)
0 R
U16
12 Reserved
0 R
U16
13
Display PID feedback in %
(b)
0 R
U16
14 Display AVI in % (1.)
0 R
U16
15 Display ACI in % (2.)
0 R
U16
16 Display AUI in % (3.)
0 R
U16
17
Display the temperature of
IGBT in oC (i.)
0 R
U16
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com