Chapter 13 CANopen Overview
|
C200 Series
13-24
Display
Fault code
Description
CANopen
fault code
CANopen
fault
register
(bit 0~7)
EoL2
Thermal relay 2
Fault
PGF4
PG Fbk deviate
Fault
002DH
PG slip error
7301H
7
EoL2
Thermal relay 2
Fault
PGF5
PG HW error
Fault
0041H
PG hardware error
7301H
5
EoL2
Thermal relay 2
Fault
PGr1
PG ref Error
Fault
002EH
Pulse input error
7300H
7
EoL2
Thermal relay 2
Fault
PGr2
PG ref loss
Fault
002FH
Pulse input loss
7300H
7
EoL2
Thermal relay 2
Fault
ACE
ACI loss
Fault
0030H
ACI loss
FF00H
1
EoL2
Thermal relay 2
Fault
EF
External Fault
Fault
0031H
External Fault
When input EF (N.O.) on external
terminal is closed to GND, AC motor
drive stops output U, V, and W.
9000H
5
EoL2
Thermal relay 2
Fault
EF1
Emergency stop
Fault
0032H
Emergency stop
When the multi-function input terminals
MI1 to MI6 are set to
emergency stop, the AC motor drive
stops output U, V, W and
the motor coasts to stop
9000H
5
EoL2
Thermal relay 2
Fault
bb
Base block
Fault
0033H
External Base Block
When the external input terminals MI1 to
MI16 are set as bb and active, the AC
motor drive output will be turned off
9000H
5
EoL2
Thermal relay 2
Fault
Pcod
Password Error
Fault
0034H
Password will be locked if three fault
passwords are entered
6320H
5
EoL2
Thermal relay 2
Fault
ccod
SW code Error
Fault
0035H
Software error
6320H
5