Chapter 14 PLC Function
|
C200 Series
14-6
(Execute/Stop) is controlled by WPL editor.
2.
When switching the page from PLC to PLC2, it will stop PLC. Again the motion of PLC
(Execute/Stop) is controlled by WPL editor.
3.
The control of external terminals follows the same method.
NOTE
When input/output terminals (FWD REV MI1~MI8 MI10~15, Relay1, Relay2 RY10~RY15, MO1~MO2 MO10~MO11,)
are used in PLC program, they cannot be used in other places. Fro example, when PLC program (PLC1 or PLC2) is
activated, such as when it controls Y0, the corresponding output terminals Relay (RA/RB/RC) will be used. At this
moment, Pr.03.00 setting will be invalid since the terminal has been used by PLC. Refer to Pr.02-52, 02-53, 03-30 to
check which DI DO AO are occupied by PLC.
14.3.2 I/O Device Reference Table
Input device
:
Device X0
X1
X2
X3
X4
X5
X6
X7
X10
X11
X12 X13 X14 X15
X16
X17
1
FWD
REV
MI1
MI2
MI3
MI4
MI5
MI6
MI7
MI8
1: I/O extension card
Output device
:
Device Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17
1
RY1
RY2
MO1
MO2
1: I/O extension card
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com