Chapter 5 Main Circuit Terminals
|
C200 Series
5-1
Chapter 5 Main Circuit Terminals
Main Circuit Diagram
* Provide 1-phase/3-phase input power
Fuse/NFB(No Fuse Brea ke r)
R(L1)
S(L2)
T(L3)
R(L1)
S(L2)
T(L3)
M otor
U(T1)
V(T2)
W(T3)
IM
3~
DC+
Bra ke resistor
(optio nal)
B1
B2
DC-
For frame A0
Terminals
Descriptions
R/L1, S/L2, T/L3
AC line input terminals 3-phase;
AC line input terminals 1-phase (R/L1, S/L2);
U/T1, V/T2, W/T3 AC drive output terminals for connecting 3-phase induction motor
DC+, DC-
Connections for brake unit (VFDB series)
B1, B2
Connections for brake resistor (optional)
Earth connection, please comply with local regulations.
* Provide 3-phase input power
Fuse/NFB(No Fu se Bre aker)
R(L1)
S(L2)
T(L3)
R(L1)
S(L2)
T(L3)
M otor
U(T1)
V(T2)
W(T3)
IM
3~
For frame A
J u m p e r
Brake resistor
(optional)
DC choke
(o ption al)
+2
B1
B2
DC-
+1/DC+
Terminals
Descriptions
R/L1, S/L2, T/L3
AC line input terminals 3-phase
U/T1, V/T2, W/T3
AC drive output terminals for connecting 3-phase induction motor
+1, +2
Connections for DC reactor to improve the power factor. It needs to remove the
jumper for installation.
+1/DC+, -/DC-
Connections for brake unit (VFDB series)
B1, B2
Connections for brake resistor (built-in)
Earth connection, please comply with local regulations.