Chapter 14 PLC Function
|
C200 Series
14-58
API
221~
223
D
OR#
S1
S2
Contact Logical operation OR#
Bit Devices
Word Devices
X Y M K H KnX
KnY KnM T
C
D
S
1
*
*
*
*
*
*
*
*
S
2
*
*
*
*
*
*
*
*
Operand:
#
: &, |, ^
Please refer to the specifications of each model for the
range of operands.
16-bit command (5 STEPS)
OR#
ZRSTP
32-bit command (9 STEPS)
DOR#
-
-
-
Flag signal: none
Explanation
1.
S
1
: Data source device 1
S
2
: Data source device 2
2. This instruction compares the content in
S
1
and
S
2
. If the result is not “0”, the
continuity of the instruction is enabled. If the result is “0”, the continuity of the
instruction is disabled.
3. OR#
(
#:
&, |, ^) is an operation instruction used on parallel contacts.
API No.
16 -bit
instruction
32 -bit
instruction
Continuity condition
No-continuity
condition
221 OR&
D
OR&
S
1
&
S
2
≠
0
S
1
&
S
2
=
0
222 OR|
D
OR|
S
1
|
S
2
≠
0
S
1
|
S
2
=
0
223 OR^
D
OR^
S
1
^
S
2
≠
0
S
1
^
S
2
=
0
4.
&:
Logical “AND” operation
5.
|:
Logical “OR” operation
6.
^:
Logical “XOR” operation
Example
When X1 = On and the result of logical AND operation of C0 and C10
≠
0, Y10 = On.
1. M60 will be On, if X2 and M30 are On with one of the following two conditions: 1.
The OR operation result of 32-bit register D10 (D11) and 32-bit register D20(D21)
does not equal to 0. 2. The XOR operation result of 32-bit counter C235 and
32bits register D200 (D201) does not equal 0.
LD=
K200
C10
Y10
LD>
D200
K-30
X1
SET
Y11