Chapter 10 Summary of Parameter Settings
|
C200 Series
10-1
Chapter 10 Summary of Parameter Settings
This chapter provides summary of parameter settings for user to gather the parameter setting ranges,
factory settings and set parameters. The parameters can be set, changed and reset by the digital keypad.
NOTE
1
)
: the parameter can be set during operation
2
)
For more detail on parameters, please refer to Ch11 Description of Parameter Settings.
00 Drive Parameters
NOTE
IM: Induction Motor; PM: Permanent Magnet Motor
Parameter
Explanation
Settings
Factory
Setting
00-00
Identity Code of the AC Motor
Drive
2:230V, 04kW
4: 230V, 1HP
5: 460 V, 1HP
6: 230V,2HP
7: 460 V, 2HP
8: 230V, 3HP
9: 460 V, 3HP
10: 230V, 5HP
11: 460 V, 5HP
12: 230V, 7.5HP
13: 460 V, 7.5HP
14: 230V, 10HP
15: 460V, 10HP
93: 460V, 5HP
(
4kW
)
Read
only
00-01
Display AC Motor Drive
Rated Current
Display by models
Read
only
00-02 Parameter
Reset
0: No function
1: Read only
5: Reset KWH display to 0
6: Reset PLC
7: Reset CANopen Index (Slave)
8: keypad lock
9: All parameters are reset to factory settings(base
frequency is 50Hz)
10: All parameters are reset to factory settings
(base frequency is 60Hz)
0
00-03
Start-up Display Selection
0: F (frequency command)
1: H (output frequency)
2: U (multi-function display, see Pr.00-04)
3: A (output current)
0
00-04
Content of Multi-function
Display
0: Display output current (A)
1: Display counter value (c)
2: Display actual output frequency (H.)
3: Display DC-BUS voltage (v)
4: Display output voltage (E)
5: Display output power angle (n)
6: Display output power in kW (P)
7: Display actual motor speed rpm (r)
8: Display estimate output torque % (t)
9: Reserved
10: Display PID feedback in % (b)
11: Display AVI in % (1.)
12: Display ACI in % (2.)
13: Display AUI in % (3.)
3