Chapter 10 Summary of Parameter Settings
|
C200 Series
10-23
07 Special Parameters
Parameter
Explanation
Settings
Factory
Setting
07-00
Software Brake Level
230V: 350.0~450.0Vdc
460V: 700.0~900.0Vdc
380.0
760.0
07-01
DC Brake Current Level
0~100%
0
07-02
DC Brake Time at Start-up
0.0~60.0 sec.
0.0
07-03
DC Brake Time at Stop
0.0~60.0 sec.
0.0
07-04
Startup Frequency for DC
Brake
0.00~600.00Hz 0.00
07-05 Reserved
07-06
Restart after Momentary
Power Loss
0: Stop operation
1: Speed search for last frequency command
2: Speed search for minimum output frequency
0
07-07
Maximum Power Loss
Duration
0.1~20.0 sec.
2.0
07-08
Base Block Time
0.1~5.0 sec.
0.5
07-09
Current Limit for Speed
Search
20~200% 50
07-10
Treatment to Reboots After
Fault
0: Stop operation
1: Speed search starts with current speed
2: Speed search starts with minimum output frequency
0
07-11
Auto Restart After Fault
0~10
0
07-12
Speed Search during
Start-up
0: Disable
1: Speed search for maximum output frequency
2: Speed search for start-up motor frequency
3: Speed search for minimum output frequency
0
07-13
Decel. Time to Momentary
Power Loss
0: Disable
1: 1st decel. time
2: 2nd decel. time
3: 3rd decel. time
4: 4th decel. time
5: current decel. time
6: Auto decel. time
0
07-14 DEB
Return
Time
0.0~25.0sec
0.0
07-15
Dwell Time at Accel.
0.00 ~ 600.00sec
0.00
07-16
Dwell Frequency at Accel.
0.00 ~ 600.00Hz
0.00
07-17
Dwell Time at Decel.
0.00 ~ 600.00sec
0.00
07-18
Dwell Frequency at Decel.
0.00 ~ 600.00Hz
0.00
07-19
Fan Cooling Control
0: Fan always ON
1: 1 minute after the AC motor drive stops, fan will be
OFF
2: When the AC motor drive runs, the fan is ON. When
the AC motor drive stops, the fan is OFF
3: Fan turns ON when preliminary heat sink
temperature (around 60
o
C) is attained.
4: Fan always OFF
0
07-20
Emergency Stop (EF) &
Force to Stop Selection
0: Coast stop
1: By deceleration Time 1
2: By deceleration Time 2
3: By deceleration Time 3
4: By deceleration Time 4
5: System Deceleration
6: Automatic Deceleration
0
07-21
Auto Energy-saving
Operation
0: Disable
1: Enable
0