background image

 

 

42 

 

 

 

6.3  Customer care support 

Contact customer care helpline numbers for any query and service related issues. 
 
 

Customer care helpline 
+91-7676254716 

 

 

 

Summary of Contents for DelREMO-V2.0

Page 1: ...1 User Guide Indoor DelREMO V2 0 www deltaelectronicsindia com...

Page 2: ...2...

Page 3: ...specifications Chapter 3 System installation procedure describes how to install and assemble various components of the DelREMO V2 0 system Chapter 4 System commissioning describes how to start and co...

Page 4: ...y such external parts does not come under warranty THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN AS IS BASIS In no event will Delta be liable for damages arising directly or indirectly...

Page 5: ...4 System Commissioning 16 4 1 Steps involved in system commissioning 16 4 1 1 System start up precautions 16 4 1 2 Starting up procedure 16 4 1 3 System Configuration 17 4 1 4 Settings Through LCD 32...

Page 6: ...e temperature sensors are placed at appropriate location where temperature needs to be monitored The area is freed of any flammable vapors or fluids To avoid electrical hazard the outer covers of all...

Page 7: ...s 1 5 2 Handling tips DelREMO V2 0 system is light weight equipment need to be handled very carefully while installing else may damage internal components 1 5 3 Preliminary inspection Before removing...

Page 8: ...e installed at small to large solar power plants User friendly front LCD display with keys helps in local configuration LED indication in front provides quick information about alarms and makes it eas...

Page 9: ...uction to different sections Before starting with installation and commission let s get introduced to the important sections of DelREMO V2 0 SYSTEM showing in fig 2 2 Introduction to different section...

Page 10: ...isplay LED indication for device function troubleshooting USB host for FW up gradation data log download Supports micro Dual SIM card 2G only Isolated input Power supply Increased data point support S...

Page 11: ...ral specification User Interface System Config Using LAN Keypad Time and Date Real time date and Programmable Event log 200K Local Monitoring Thru Ethernet Port Embedded Web server LCD General Op Temp...

Page 12: ...installation Installation procedure of DELREMO SYSTEM involves the following standard steps Make sure that these steps are checked and followed throughout the installation procedure Tools Required Pre...

Page 13: ...the factory System mounting and input output connections along with necessary connections to various power sources and connections are made at the installation site DelREMO V2 0 is to be mounted on wa...

Page 14: ...odular interconnection procedure involves interconnection to various modules of the system on RS 485 daisy chain to make it functional WARNING While connecting the adapter output to DelREMO System pol...

Page 15: ...Steps for input connection Check 1 Connect all the sensors output to DelREMO at their respective position provide power from system is required 2 Connect inverters over RS485 port ACEM 3 Connect Digit...

Page 16: ...ns for any damage or loose connections before starting up procedure of DelREMO V2 0 Follow the below step wise procedure strictly for startup procedure of DelREMO V2 0 Step wise starting process will...

Page 17: ...IV After clicking on change adapter settings the window will appear as shown right click on the icon Local area connection as shown below V Now click on properties as highlighted VI After clicking Pr...

Page 18: ...18...

Page 19: ...PATH Control Panel Internet Option IX At Internet Properties TAB click on Connections then click on LAN Settings TAB a Un tick Proxy server b Click on OK As shown in figure NOTE TURN OFF ALL PROXY SE...

Page 20: ...20 X Now open Google Chrome browser on your laptop XI In Address Bar type the following IP address 192 168 100 30 and press Enter Key Pushpak II Controller Web page configuration...

Page 21: ...er clicking on Click here for Login Tab a pop up window will appear enter user name and password as captioned below Fill User Name admin to logged in Password delta XIII After Log in Window will appea...

Page 22: ...9 Menu tab 5 Site ID site Name XIV Upload firmware file by following Path Upload Firmware DelRemo Click on Choose File Tab to select Firmware version as shown Choose the desired firmware file to be up...

Page 23: ...o Set Verify Modem Setting go to Interface Modem and do settings as mentioned below User can Enable Disable desired SIM SIM 1 Status ENABLE SIM 2 Status DISABLE APN Manual Internet IDEA SIM airtelgprs...

Page 24: ...f inverter available at site which is going to be monitored at Inverter Settings Do select energy meters Model if available at site otherwise keep this setting as Disable Also put no of energy meters...

Page 25: ...pulate below setting Configure NOC IP Domain Name DelREMO emonitoring co in Port 4015 Interface Ethernet Primary Server GPRS Backup Server SMS No 918750069315 Periodicity 5 Server IP 172 24 2 18 Serve...

Page 26: ...enter DelREMO Ethernet configuration setting Configure Ethernet and submit thereafter to save the setting XX Follow Below path to enter Auto Update setting Configuration Auto update Settings Do settin...

Page 27: ...Customer can use this method if wants to synchronize DelREMO on their NTP server 2 NITZ Network Identity and Time zone is a mechanism often used to update system clock automatically using GSM network...

Page 28: ...No as user1 919540524222 user2 918527000445 user3 91XXXXXXXXXX user4 91XXXXXXXXXX user5 91XXXXXXXXXX From user3 to user5 mobile no of Site Technician CI ZOM etc can be configured as per customer requ...

Page 29: ...ture of reading it provided Type This field enables disabled the effect of offset and multiplier into the original value supplied by sensor None should be set under type if sensor customization does n...

Page 30: ...to generate power in steps Can be customized whenever it found the generated power is exceeding the power required at load to avoid unwanted power loss This feature is optional to any requirement but...

Page 31: ...31 XXVI One can learn energy meter parameters through tapping on EM Status XXVII Tap on Inverter status to learn various parameters coming from Inverter configured with DelREMO...

Page 32: ...CONFIG 3 Select GSM CONFIG using UP Down Key Press ENTER key After pressing Enter key two options will come SIM 1 SIM 2 4 Select SIM 1 press ENTER Key further two options will come ENABLE DISABLE Sele...

Page 33: ...ion message will appear as SETTING SAVED SUCCESSFULLY 7 Now go to ETH CONIG in main Menu Select ETH CONFIG press ENTER Key Following Options will come MODE IP ADDRESS SUBNET MASK GATEWAY PRIMARY DNS S...

Page 34: ...MASK Configuration Follow below path by pressing ENTER ETH CONFIG SUBNET MASK By pressing UP or DOWN key you can change the desired digit For moving to the other digit press ENTER key Follow step 5 6...

Page 35: ...RATION Follow below path by pressing ENTER ETH CONFIG SECONDARY DNS By pressing UP or DOWN key you can change the desired digit For moving to the other digit press ENTER key Follow step 5 6 to save ch...

Page 36: ...1 6 Check points before leaving the site Check following points carefully before leaving the site NOTE THIS ENSURES THE COMMISSIONING OF THE SYSTEM IF FACING ANY TROUBLE DURING COMMISSIONING REFER TRO...

Page 37: ...authorized access by username and password Step 1 Login to the PUSHPAK II using Google Chrome browser using IP Address 192 168 100 30 Step 2 Go to Configure Site to set NOC Configuration and inverters...

Page 38: ...e access of the system 4 2 Modes of operation DelREMO V2 0 can send data to remote server thru following modes 4 2 1 Mains Mode This mode confirms that a main AC is available to 24 VDC adapter adapter...

Page 39: ...y diagnosis purposes only Kindly contact customer support department before replacement of faulty parts or for more information during troubleshooting This section covers faults which may possibly occ...

Page 40: ...alid SIM card is inserted and valid SIM is enabled 2 Ensure for valid APN and SIM setting Server not Reachable 1 Invalid NOC setting 2 Remote host server not responding 1 Check NOC server settings 2 R...

Page 41: ...Use soft cloth to clean equipment 6 2 Do s and Don ts Do s Do make sure equipment is in proper working order and operating in a safe manner Attention and commitment to routine maintenance goes a long...

Page 42: ...42 6 3 Customer care support Contact customer care helpline numbers for any query and service related issues Customer care helpline 91 7676254716...

Page 43: ...anual should not be understood as advertising for the product or their manufacturers The authors reserve the rights to make any changes to this product and to revise the information about the products...

Page 44: ......

Page 45: ...Recycle paper Save earth...