Chapter 3 Featured Function
3-52
Description
Factory Default
Remote Management
Specify whether remote user can manage DVW device by SNMP.
None
Read Community
Input a community name for the device to be accessed with read-only
permission.
public
Write Community
Input a community name for the device to be accessed with read/write
permission.
private
SNMP Agent Version
Specify the SNMP version of the device.
V1, V2c
Admin Authentication Type
Specify the admin authentication type to verify that the message is
from a valid source. It works when SNMP agent version is “V1, V2c,
V3” or “V3”.
No Auth:
No Authentication. Only use admin account to access
objects.
MD5:
Use MD5 algorithms for authentication.
SHA:
Use SHA algorithms for authentication.
No Auth
Admin Privacy Type
Specify the data encryption type. It works when SNMP agent version is
“V1, V2c, V3” or “V3”.
Disable:
No data encryption.
AES:
Use AES-based data encryption.
DES:
Use DES-based data encryption.
Disable
Privacy Key
Input a data key for data encryption.
None
Device Object ID
This field displays the Delta DVW device’s OID.
Fixed
Summary of Contents for DVW SERIES
Page 1: ......
Page 5: ...iv Appendix B MODBUS TCP Map B 1 MODBUS TCP Map B 2 ...
Page 6: ...v ...
Page 14: ...DVW Series Industrial IEEE 802 11 a b g n Wireless AP WDS Client Gateway User Manual 1 8 MEMO ...
Page 100: ...DVW Series Industrial IEEE 802 11 a b g n Wireless AP WDS Client Gateway User Manual 4 12 ...
Page 101: ...Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 A 1 ...
Page 103: ...Appendix B MODBUS TCP Map Table of Contents B 1 MODBUS TCP Map B 2 B 1 ...