background image

104437   Rev. A

Clean and Care

Care should be given to the cleaning

of this product. Although its finish is

extremely durable, it can be damaged by

harsh abrasives or polish. To clean, simply

wipe gently with a damp cloth and blot dry

with a soft towel.

Maintenance

Faucet leaks from showerhead:

SHUT OFF WATER SUPPLIES.

Replace seats and springs–Repair

Kit RP4993. Check condition of lower O-rings and

replace if necessary RP14414. See Helpful Hints 1,

2, & 3.
If leak persists:

SHUT OFF WATER SUPPLIES.

Replace valve cartridge RP46074.

See Helpful Hints 1, 2, 3, 4 & 5
Unable to maintain constant

water temperature:

Replace housing assembly with RP46074 or follow

instructions in Helpful Hints 1, 2, 3, 4 & 5.
Helpful Hints:

1. Before removing valve cartridge assembly for any

maintenance, be sure to note the position of the

rotational limit stop on the cap. The valve cartridge

assembly must always be put back in the same

position. BE SAFE! After you have finished the

installation, turn on valve to make sure COLD

WATER FLOWS FIRST.

2. To remove valve cartridge from body, shut off

water supplies and remove handle and bonnet nut. 

Do not pry the valve cartridge out of the body with 

a screwdriver. Place handle on stem and rotate

counterclockwise approximately 1/4 turn after the

stop has been contacted. Lift valve cartridge out

of body.
3. To remove seats and springs.

Remove valve cartridge. Separate cap assembly

from the housing assembly by rotating the cap

assembly counterclockwise 90

°

 (degrees).

Separate cap and housing assemblies.
4. If the water in your area has lime, rust, sand

or other contaminants in it, your pressure

balance valve will require periodic inspection.

The frequency of the inspection will depend

on the amount of contaminants in the water. To

inspect valve cartridge remove it and follow the

steps in note 1 above. Turn the valve to the full

mix position and shake the cartridge vigorously.

If there is a rattling sound, the unit is functional

and can be reinstalled following instructions given

in note 1 above. If there is no rattle, replace the

housing assembly with the proper RP.
5. Push disc until fully seated. See page 6 for 

more details

8

Summary of Contents for MultiChoice T24 Series

Page 1: ... how to properly make these adjustments please refer to page 5 and if still uncertain call us at 1 800 345 DELTA After installation and adjustment you must affix your name company name and the date you adjusted the Rotational Limit Stop to the caution label provided and apply or attach the label to the back side of the closest cabinet door and the warning label to the water heater Leave this Instr...

Page 2: ...ervice Technical Service Centre 55 E 111th Street 350 South Edgeware Road Indianapolis IN 46280 St Thomas Ontario Canada N5P 4L1 Attention Customer Solutions Attention Customer Service www deltafaucet com service parts contact us http www deltafaucet ca customersupport assistance html Proof of purchase original sales receipt from the original purchaser must be made available to Delta Faucet Compan...

Page 3: ...nd thread onto the body Hand tighten securely Slide o ring 6 over cartridge and bonnet A light coating of plumbers grease applied to o rings may aid in assembly For the exceptions of back to back or reverse installations hot on right and cold on left only Rotate valve cartridge 1 so HOT COLD 2 appears on the bottom Apply silicone lube to the three o rings shown above to make the cartridge easier t...

Page 4: ...cone lube to the o ring 2 to make the diverter sleeve 3 easier to install diverter cartridge A light coating of plumbers grease applied to o rings 4 may aid in assembly Install diverter cartridge 1 assuring that the locating pin on the bottom of the cartridge aligns with mating hole in rough in body Slide diverter sleeve 3 over cartridge stem aligning tabs on the diverter sleeve with slots in roug...

Page 5: ... seasonally if the inlet water temperature changes For example during the winter the cold water temperature is colder than it is during the summer which could result in varying outlet temperatures A water temperature for a comfortable bath or shower is typically between 90 F 110 F Run the water so that the cold water is as cold as it will get and hot water is as hot as it will get Place the handle...

Page 6: ...ded onto diverter sleeve Note For thick wall installations order installation kit RP90542 to support finished wall thickness up to 2 1 8 On rough or uneven surfaces it is necessary to apply caulk around the backplate 1 to supplement the seal Do not caulk the drip notch in the bottom of the backplate 1 Do not caulk the escutcheon 4 1 2 A B 1 2 5 4 3 3 Valve Handle Installation Using an allen wrench...

Page 7: ...ortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salid...

Page 8: ...valve to make sure COLD WATER FLOWS FIRST 2 To remove valve cartridge from body shut off water supplies and remove handle and bonnet nut Do not pry the valve cartridge out of the body with a screwdriver Place handle on stem and rotate counterclockwise approximately 1 4 turn after the stop has been contacted Lift valve cartridge out of body 3 To remove seats and springs Remove valve cartridge Separ...

Reviews: