Responsive actions that should be taken in cases where the following symptoms occur are described.
Symptom
Verification details
Responsive action
System ready light is red
DC1 is booting
Please wait two minutes for the boot to complete
Inverter comm light is
continuously
flashing
green light
DC1 is Searching or Setting
inverters.
Please wait for 2-10 minutes for Inverter to search or
set up.
Internet light constant
The LED Light of ‘Status’ flashes
slow and changing color between
green and yellow
The LED Light of ‘Status’ turns
red and slow flashing
The LED Light of ‘Status’ turns
red and fast flashing
DC1 does not connect to internet Please go to the NETWORK page to set network.
For detailed setting process, please refer to section 6.6.
N1 or N2 is booting
Please wait a minutes for the boot to complete.
Initialize N2’s RF module failed
when connecting to an inverter.
Please confirm if there is a connection between N2 and
Inverter. if not, refer the figure in Chapter 2 and connect
each wire to the communication card of the Inverter
correctly.
N1 does not connect to Data Collector
N2 does not connect to Inverter
Please confirm if N1 is assembled with Data Collector/
Please confirm if N2 is adapted to Inverter.
8.2.Troubleshooting