INSTALLATION

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air
compressor should be located at least 12" away from the wall or other
obstructions that will interfere with the flow of air. The air compressor pump
and shroud are designed to allow for proper cooling. The ventilation openings
on the compressor are necessary to maintain proper operating temperature. Do
not place rags or other containers on or near these openings.

HOW TO SET UP YOUR UNIT

9- ENG

D27930

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK.  In the event of a short
circuit, grounding reduces the risk of shock by providing

an escape wire for the electric current. This air compressor must be
properly grounded.

The portable air compressor is equipped with a cord
having a grounding wire with an appropriate
grounding plug (see illustrations).  The plug must be
used with an outlet that has been installed and
grounded in accordance with all local codes and
ordinances. 

1.

The cord set and plug with this unit contains a
grounding pin. This plug MUST be used with a
grounded outlet. 

IMPORTANT: The outlet being used must be
installed and grounded in accordance with all local
codes and ordinances. 

2.

Make sure the outlet being used has the same
configuration as the grounded plug. DO NOT
USE AN ADAPTER. 

When used outside of the United
States of America a conversion kit may be required for

local use. 

3.

Inspect the plug and cord before each use.  Do not use if there are signs
of damage.

4.

If these grounding instructions are not completely understood, or if in
doubt as to whether the compressor is properly grounded, have the
installation checked by a qualified electrician.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL
SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a
correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

120 Volt U.S.A. Plug

240 Volt U.S.A. Plug

Grounding

Pin

Grounding

Pin

Summary of Contents for ShopMaster CP200

Page 1: ...ight 2002 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Oil Free Air Compres...

Page 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Page 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Page 4: ...ediately with a new tank or replace the entire compressor 1 Failure to properly drain condensed water from tank causing rust and thinning of the steel tank 2 Modifications or attempted repairs to the...

Page 5: ...the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream...

Page 6: ...can cause serious injury if they com into contact with you or your clothing HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF FALLING A portable compressor can fall from a table workbench or roof cau...

Page 7: ...at all times Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a...

Page 8: ...r accessory When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressu...

Page 9: ...has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTAN...

Page 10: ...if operation of the compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit It is not necessary to change the cord set Extension Cords Using exte...

Page 11: ...k Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and turn clockwise to i...

Page 12: ...ir receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use How to Use Your Unit How to Stop 1 Set the Auto On Off switch to OFF NOTE It is normal for the fan...

Page 13: ...k by opening drain valve counter clockwise on bottom of tank NOTE Tilt tank forward to drain tank completely Water will condense in the air tank If not drained water will corrode and weaken the air ta...

Page 14: ...mately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air ta...

Page 15: ...tings with pipe sealant tape and retighten securely Do Not Overtighten If leaks continue contact a Trained Service Technician Air leaks at fittings Air leaks in air tank or at air tank welds Defective...

Page 16: ...s Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCF...

Page 17: ...electrical appliances from circuit or operate the compressor on its own branch circuit Have checked by a Trained Service Technician Fuse blown circuit breaker tripped Extension cord is wrong length or...

Page 18: ...rs with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangements If...

Reviews: