Setup Item
Setting Parameters*
1
The code
shown on the
16-segment
display
Meaning
AST
Auto-Start To On-line Setup
OFF (Default), ON
*
6
PF
Power Factor Setup
70, 80, 90 (Default)
RST
Restore Default Setup
NA (Default), DEF
*
7
NOTE:
1.
*
1
: The setting parameters are described in text format; please refer to actual icons or codes shown
on the LCD display when performing the setup action.
2.
*
2
: If the setting is set to '
ON
', the UPS will automatically disable the bypass function.
3.
*
3
: If the setting is set to '
OFF
', the UPS will run in standby mode whenever the utility AC power is
connected to the UPS or whenever you press the OFF
OFF
button in on-line mode.
If the setting is set to '
ON
', the UPS will run in bypass mode whenever the utility AC power is
connected to the UPS or whenever you press the OFF
OFF
button in on-line mode.
In standby mode, the UPS has no output voltage; in bypass mode, the UPS has output voltage. In
either standby mode or bypass mode, the batteries will be charged.
4.
*
4
: The percentage here indicates the bypass tolerance range for the current '
Inverter Voltage
'
setting. For HI1, the tolerance range is -20% ~ +15%; for HI2, -25% ~ +15%; for HI3, 120Vac ~
276Vac.
5.
*
5
: If the UPS is not connected to the external battery pack(s), you don’t need to adjust the setting.
Just keep the default setting as '
0
'.
If the UPS is connected to the external battery pack(s), you have to set up '
CAP
' and '
STG
' these
two items based on the battery capacity and the strings of the external battery pack(s). If the
parameters of the external battery pack(s) do not match the UPS’s built-in setting options, please
choose the closest parameters for the battery setting.
6.
*
6
: This setup item only affects the UPS’s operation mode whenever the utility AC power is connected
to the UPS.
If the setting is set to '
OFF
', the UPS will operate according to the '
STB
' setting.
If the setting is set to '
ON
', the UPS will start up and run in on-line mode automatically.
7.
*
7
: When you select '
DEF
', each of the parameters will be restored to the default value. If any setting
deviates from the default value or is different from what you expect, you may adjust the setting.
z
z
For setup procedures, please refer to the following:
1
Simultaneously press the two buttons
ON
SETUP
for 3 seconds to enter the setup mode.
2
Press the
ON
button for 0.1 second or press the
OFF
button for 0.1 second to view the previous or
the next display.
3
Press the
button for 0.1 second to enter the item that you want to set up.
4
Press the
ON
button for 0.1 second or press the
OFF
button for 0.1 second to increase or decrease
the parameter value.
5
Press the
button for 0.1 second to confirm your parameter setup.
6
After that, press the
ON
button for 0.1 second or press the
OFF
button for 0.1 second to go to the
previous or the next setup item.
7
In setup mode, simultaneously press the two buttons
ON
SETUP
for 3 seconds, the LCD will exit from the
setup mode.
8
In setup mode, if you don’t press any button for more than 2 minutes, the LCD will exit from the setup
mode and go back to the original display automatically.
z
z
Setup Mode Flow Chart
1
3
2
2
4
5
6
3
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
3
2
4
5
6
*
1
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
7
8
or
Original Display
Inverter Frequency Setup
Frequency Converter Setup
Standby Bypass Setup
ECO Setup
Overload Alarm Setup
Buzzer Setup
Bypass Range Setup
Battery String Setup
Battery Capacity Setup
Auto-Start To On-line Setup
Power Factor Setup
Restore Default Setup
Inverter Voltage Setup
NOTE:
*
1
:
In standby mode or in bypass mode, if you change the '
AST
' setting from '
OFF
' to '
ON
' and
execute the step
5
to confirm such change, the UPS will exit from the setup mode and run in
'
Auto-Start to On-line
' mode right away.
6.3 LCD Display
Hz
KW
KVA
AH
MIN
MIN
ECO
V
V%
IN
SET IN OUT BATT
RUN TIME
°C
LOAD TEST
Icon(s)
Naming
Description
AC Icon
Indicates the input power status.
1.
ON
: Within the acceptable bypass range.
2.
Flashing
: Out of the acceptable bypass range but sufficient to let
the UPS operate in on-line mode.
3.
OFF
: Out of the acceptable bypass range and not sufficient to let the
UPS operate in on-line mode.
Output Icon
Indicates the output status.
1.
ON
: There is output.
2.
OFF
: There is no output.
Battery Power
Icon
Indicates the battery power status.
1.
ON
: The battery power is on.
2.
OFF
: The output is not supplied by the batteries.
ECO
Standby Mode
Graph
Illuminates when the UPS is operating in standby mode.
Icon(s)
Naming
Description
ECO
On-line Mode
Graph
Illuminates when the UPS is operating in on-line mode.
ECO
Battery Mode
Graph
Illuminates when the UPS is operating in battery mode.
ECO
ECO Mode Graph
Illuminates when the UPS is operating in ECO mode.
ECO
Frequency
Converter Mode
Illuminates when the UPS is operating in frequency convert mode (the
icon
ECO
will flash while these two icons
&
remain on).
ECO
Bypass Mode
Graph
Illuminates when the UPS is operating in bypass mode.
ECO Mode
Illuminates when the UPS is operating in ECO mode.
1.
ON
: ECO function is enabled and the connected loads are fed by the
utility AC power.
2.
Flashing
: ECO function is enabled and the connected loads are fed
by the double conversion.
Buzzer Off
Icon
Illuminates when the buzzer is disabled.
Load Level
Bar Graph
Indicates the load level status.
ON
: load level (%)
*
1
.
NOTE:
When the UPS is overloaded, the warning icon
will flash and the 7-segment display will flash with a load level
value.
Battery Level Bar
Graph
Indicates the battery level status.
1.
ON
( ): The remaining battery capacity (%)
*
1
.
2.
Flashing
( ): Low battery.
3.
Flashing
(
Hz
KW
KVA
AH
MIN
V
%
SET IN OUT BATT
°C
LOAD
TEST
): There is no battery or battery replacement is
required.
*
2
.
NOTE:
1.
*
1
:
means that:
1%~25%: the 1st segment will illuminate.
26%~50%: the first two segments will illuminate.
51%~75%: the first three segments will illuminate.
76%~100%: all segments will illuminate.
2.
*
2
: If you need to replace the external battery pack(s), please contact service personnel.
6.4 7-segment Display
Hz
KW
KVA
AH
MIN
MIN
ECO
V
V%
IN
SET IN OUT BATT
RUN TIME
°C
LOAD TEST
Hz
KW
KVA
AH
MIN
MIN
ECO
V
V%
SET IN OUT BATT
°C
LOAD TEST
7-Segment Display
Column A
Column C
Column B
NOTE:
Please read the columns A, B and C together to understand the LCD information, such as input
voltage, estimated remaining backup time, etc.
Column A
Meaning
Column C
Meaning
The 7-segment display
shows readings or words.
AH
Ampere hour
Column B
Meaning
V
Voltage
SET
Setup mode
%
Percentage
IN
Input
Hz
Frequency
OUT
Output
KVA
kVA
BATT
Battery
KW
kW
LOAD
Load
MIN
Minute
TEST
Test
°C
The UPS’s internal temperature
Continue to the Next Page