During operation, the gate should not under any circumstances obstruct public path ways and roads (public area).

When using tools and small parts to install or carry out repair work on a gate exercise caution and do not wear rings, watches or loose clothing.

To avoid serious personal injury due to entrapments, remove any locking device fitted to the gate in order to prevent damage to the gate.

Installation and wiring must be in compliance with your local building and electrical installation regulations. Power cables must only be connected to a properly earthed 

supply.

Disconnect electric power to the system before installation, maintenance, repairs or removing covers.  A disconnecting device must be provided to the mains power supply 

(permanently-wired installation) to guarantee all-pole disconnection (isolating switch or by a separate fuse). The repairs and electrical installations may be performed only 

by an authorised electrician. Emergency Stop Button must be installed for emergency case based on the risk assessment.

Ensure that entrapment between the driven part and the surrounding fixed parts due to the opening movement of the driven part is avoided by respecting the given safety 

distances in accordance with the EU: EN 13241, EN12604, EN 12453, EN 12635; GB (UK, NI) BS EN 13241, BS EN12604, BS EN 12453, BS EN12635 and/or with 

safety devices (e.g. safety edge).

Testing of the safety function of the drive system is recommended to be carried out at least once a month. Refer also to manufacturers instruction of the gate system 

components. 

After the installation a final test of the full function of the system and the of the safety devices must be made and all users must be instructed in the function and operation 

of the swing gate operator.

Gate systems must meet the force limitation according EU: EN 12453, EN 60335-2-103; GB (UK, NI) BS EN 12453, BS EN 60335-2-103. 

Additional safety device (safety edge,.) must be considered in accordance to the standard by changes to the system.

It is important to make sure that the gate always runs smoothly. Gates which stick or jam must be repaired immediately. Employ a qualified technician to repair the 

gate, never attempt to repair it yourself. This device is not intended for use by persons (including children) with restricted physical, sensory or mental abilities or lack of 

experience or knowledge, unless they are supervised by a person responsible for their safety or have received instruction in how to use the device. If necessary, control 

equipment MUST be mounted within sight of the gate and out of reach of children. Children should be supervised to ensure that they do not play with the device. Do not 

allow children to operate push button(s) or remote(s). Misuse of the gate operator system can result in serious injury. 

The warning signs should be placed in clearly visible locations.

The gate opener should ONLY be used if the user can see the entire gate area and is assured that it is free of obstacles and the gate operator is set correctly. No one may 

pass through the gate area while it is moving. Children must not be allowed to play in the vicinity of the gate.

The full protection against potential crushing or entrapment must work immediately when the drive arms are installed.

There may be existing hazards on mechanical, electrical installation or the closing edges of the gate by crushing, impact points:

• 

Structural failure, leaf, hinges, fixings, travel stops, wind load

• 

Crush, hinge area, under the gate, safety distance on fixed object

•  Electrical failure (Control – faults in safety systems)

•  Impact, swept area, hold to run, force limitation, presence detection

Appropriate measures must be taken to ensure safe operation of the gate system according the standards.

Never start up a damaged drive.

Use the manual release only to disengage the drive and – if possible – ONLY when is gate closed. Operation of the emergency manual release can lead to uncontrolled 

movements of the gate.  The Timer-to-Close (TTC) feature, the myQ Smartphone Control app, are examples of unattended operation of the gate. 

Any device or feature that allows the gate to close without being in the line of sight of the gate is considered as unattended open/close. 

The Timer-to-Close (TTC) feature, the myQ Smartphone Control, and any other myQ devices can ONLY be activated when Liftmasters photo cells are installed (TTC 

works only in close direction). The gate shall only be operated in the direct sight line to the gate.

IMPORTANT INFORMATION!

• 

This procedure is also required on private installations (new or retrofitted to a manually operated gate).

 

This installation and operating manual must be retained by the user.

•  The manufacturer accepts no liability/warranty claims resulting from use other than intended use and after the warranty expires.

•  The legal remedy is the sole responsibility for all associated rights.

NOTE:

 Observe the installation and operating manual.

•  Always monitor the function of the system and rectify the cause immediately in the event of a malfunction.

•  Carry out an annual inspection of the system. Call a specialist.

•  Safety distances must be respected between the gate leaf and the environment in accordance with related standards.

•  The operator can be installed Only on stable and rigid gate leaves. Gate leaves must not bend or twist when opening and closing.

•  Assure that the hinges of the gate leaf are installed and working correctly and not creating any obstacles.

•  Installation of two operators on same door leaf is strictly prohibited. 

1. SAFETY INSTRUCTIONS AND INTENDED USE

Summary of Contents for LiftMaster AA250EVK

Page 1: ...Installation Manual fr Manuel d installation de l op rateur de porte battante nl Installatiehandleiding draaihekaandrijving For GB UK NI specific information on national regulations and requirements...

Page 2: ...6 Programming and Erasing of Remote Controls Radio Accessories and myQ Devices 13 7 7 Advanced Settings 14 7 7 1 Overview Advanced Settings 14 7 7 2 Transmitter Settings 14 7 7 3 Infrared Photocells...

Page 3: ...uctions to avoid personal injury or damage to property Read these instructions carefully Warnings Symbols The general warning symbol indicates a danger that can lead to injuries or death In the text s...

Page 4: ...low children to operate push button s or remote s Misuse of the gate operator system can result in serious injury The warning signs should be placed in clearly visible locations The gate opener should...

Page 5: ...4x Gate Mounting Bracket 2x Circlip 2x Circlip pin 2x Release Key 4x Remote Control 2x Primary unit with Control Board Secondary unit Installation Manual LA250EVK LA300EVK 1 Motor 1 with control board...

Page 6: ...le installation AA250EVK 1 5 m 250 kg 2 0 m 200 kg 2 5 m 150 kg Operator Arm Mounting 1 Attach the motor arm to the center of the opener from the underside 2 Secure the caps with the screw and washer...

Page 7: ...Position the gate bracket in the desired full closed position as shown in the picture 3 c Temporarily secure it to the gate leaf do not make permanent connection to gate leaf yet to enable adjustments...

Page 8: ...o disengage the release mechanism remove the plastic cover enter the key and turn it 90 Pull the clutch up see picture 4 To re engage the release meachanism push the clutch down and turn the key 90 3...

Page 9: ...ry motor extension cable through one of the cable glands at the bottom of the Primary unit see picture 8 Ensure to use the side of the motor where the arm cannot cut the cables during opening or closi...

Page 10: ...E LK SYNC STBY UART LIMIT SW connectors are not used for AA units MOTOR 2 WHT GRN RED WHT GRN RED MOTOR 1 M M BAT BAT 24V BATTERY POW 24V SPEC 24VDC SYNC STBY UART LIMIT SW E LK FLA COMMAND IR SENSOR...

Page 11: ...hold P button for 5 seconds to enter the menu AP on the display indicates the first available function in menu 2 Use and buttons to navigate between the functions 3 Press P button to select the requir...

Page 12: ...d on the righ hand side Motor 1 is moving in closing direction when installed on the left hand side default Motor 2 is moving in closing direction when installed on the right hand side default Motor 2...

Page 13: ...Wing 2 actions are not used Following settings are programmed during Advanced Learning mode 1 Travel length from FULL CLOSED to FULL OPEN position 2 Opening and closing force for each motor 3 Starting...

Page 14: ...IRs is mandatory for myQ operation 2 Create an account Download the free myQ App from App Store or Google Play Store and create an account If you already have an account use your username and passwor...

Page 15: ...ories are executed Each of the 3 Inputs can be programmed individually NOTE Under settings 01 02 and 03 TTC timer will be overridden by an Input command and will CLOSE the gate Under setting 06 active...

Page 16: ...are interrupted the TTC timer shall re start 2 seconds reversal and Stop Reversal back up to the end limit position Default During Closing movement upon impact gate reverses up to Open position During...

Page 17: ...is reached If PF Function Pre Flashing is active then 4 second pre flashing will be added to the set time To reset counter after maintenance is done it will be enough to program the cycles one more ti...

Page 18: ...tings All settings apart from Radio Memory will be deleted See page 18 P S P S P S P S III I I I III I I I 2 sec III I I I or or 7 PROGRAMMING 7 7 15d Force Motors 1 and 2 in Open and Close Directions...

Page 19: ...ult 10 20 30 50 10 20 7 7 15f Soft Stop Speed Soft Stop Speed function allows adjustment of the Soft Stop speed compared to default values set during Learning phase Soft Stop speed is 50 of the standa...

Page 20: ...to check if control board recovers If not change control board F6 Gate reverse during closing Low battery power Charge battery F7 Press transmitter but no gate movement Control board damaged Switch of...

Page 21: ...ur statutory rights are not affected by this manufacturer s warranty Please see www liftmaster eu for terms of warranty Our electrical and electronic equipment may not be disposed of with household wa...

Page 22: ...commandes accessoires radio et appareils myQ 13 7 7 R glages avanc s 14 7 7 1 Vue d ensemble r glages avanc s 14 7 7 2 R glages de l metteur 14 7 7 3 R glages des cellules photo lectriques infrarouge...

Page 23: ...age mat riel Veuillez lire ces instructions attentivement Symboles d avertissement Le symbole g n ral d avertissement indique un danger pouvant entra ner des blessures voire la mort Dans la section te...

Page 24: ...es Le syst me d ouverture de la porte ne doit tre utilis QUE si l utilisateur peut voir toute la zone du portail et qu il est s r qu il n y a pas d obstacle et que l automatisme de la porte est r gl c...

Page 25: ...2x Circlips 2x Tiges pour circlip 2x Cl s de d verrouillage 4x T l commandes 2x Unit primaire avec panneau de commande Unit secondaire Manuel d installation LA250EVK LA300EVK 1 Moteur1avecpanneaudecom...

Page 26: ...nstallation type AA250EVK 1 5 m 250 kg 2 0 m 200 kg 2 5 m 150 kg Montage du bras de l automatisme 1 Fixez le bras du moteur au centre du dispositif d ouverture par le dessous 2 S curisez les bouchons...

Page 27: ...position enti rement ferm e souhait e comme illustr sur l image 3 c Fixez le temporairement au vantail du portail ne le fixez pas encore de fa on permanente au vantail pour permettre les r glages et r...

Page 28: ...nisme de d verrouillage retirez le couvercle en plastique ins rez la cl et tournez la 90 Tirez l embrayage vers le haut voir l image 4 Pour r armer le m canisme de d verrouillage poussez l embrayage v...

Page 29: ...c ble d extension du moteur secondaire par un des presse toupes en bas de l unit primaire voir l image 8 Assurez vous d utiliser le c t du moteur o le bras ne risque pas de couper les c bles durant le...

Page 30: ...24VDC SYNC STBY UART LIMIT SW E LK FLA COMMAND IR SENSOR EDGE 24V BAT 8 2K SAFETY EDGE NC NO NO Stop Fully Open Partial Open LAMP 1 FLASH LAMP SE SE GND GND IR3 IN3 IN2 IN1 IR2 IR1 L L N N PE AC 230V...

Page 31: ...ont connect s 1 Appuyez sur le bouton P et maintenez le enfonc pendant 5 secondes pour entrer dans le menu AP l cran indique la premi re fonction disponible dans le menu 2 Utilisez les boutons et pour...

Page 32: ...ace dans le sens de la fermeture lorsqu il est install gauche par d faut Le moteur 2 se d place dans le sens de la fermeture lorsqu il est install droite par d faut Le moteur 2 se d place dans le sens...

Page 33: ...ndes REMARQUE dans l application moteur unique les actions Vantail 2 ne sont pas utilis es Les param tres suivants sont configur s durant le mode d apprentissage avanc 1 Course entre les positions ENT...

Page 34: ...l appli gratuite myQ depuis l App Store ou le Google Play Store et cr ez un compte Si vous avez d j un compte utilisez votre nom d utilisateur et votre mot de passe 3 Enregistrer la passerelle intern...

Page 35: ...la fa on dont les commandes d entr e des accessoires externes sont ex cut es Chacune des 3 entr es peut tre programm e individuellement REMARQUE avec les param tres 01 02 et 03 la minuterie TTC est c...

Page 36: ...ersion de 2 secondes et arr t Inversion pour retourner jusqu la position de fin de course par d faut Durant le mouvement de fermeture le portail repart en position Ouvert en cas d impact Durant le mou...

Page 37: ...clignotement de 4 secondes est ajout au temps r gl Pour r initialiser le compteur apr s la maintenance il suffit de programmer les cycles une fois de plus pas de compteur par d faut 1000 cycles 2000...

Page 38: ...ut Tous les param tres sauf la m moire radio seront supprim s Voir page 18 P S P S P S P S III I I I III I I I 2 s III I I I ou ou 7 7 15d Force des moteurs 1 et 2 dans les sens ouverture et fermeture...

Page 39: ...vitesse arr t en douceur permet de r gler la vitesse de l arr t en douceur par rapport aux valeurs par d faut d finies durant la phase d apprentissage La vitesse arr t en douceur correspond 50 de la v...

Page 40: ...s Le module radio a chou Couper l alimentation pendant 20 secondes et r initialiser pour v rifier si le panneau de commande se remet en marche Si ce n est pas le cas remplacer le panneau de commande F...

Page 41: ...Ne tenez pas compte des instructions de configuration Vos droits statutaires ne sont pas remis en cause par cette garantie du fabricant Veuillez consulter www liftmaster eu pour conna tre les conditio...

Page 42: ...radioaccessoires en myQ apparaten 13 7 7 Geavanceerde instellingen 14 7 7 1 Overzicht geavanceerde instellingen 14 7 7 2 Zenderinstellingen 14 7 7 3 Infrarood fotocellen Instellingen 14 7 7 4 Invoeri...

Page 43: ...ersoonlijk letsel of schade aan eigendommen te voorkomen Lees deze instructies zorgvuldig Waarschuwingssymbolen Het algemene waarschuwingssymbool wijst op een gevaar dat kan leiden tot letsel of de do...

Page 44: ...orden gebruikt als de gebruiker het hele poortgebied kan overzien en er zeker van is dat het vrij is van obstakels en dat de poortopener juist is ingesteld Niemand mag door het poortgebied terwijl het...

Page 45: ...Poort montagebeugel 2x Borgring 2x Borgpen 2x Ontgrendelingssleutel 4x Zender 2x Primaire eenheid met bedieningspaneel Secundaire eenheidt Installatiehandleiding LA250EVK LA300EVK 1 Motor 1 met bedien...

Page 46: ...atie AA250EVK 1 5 m 250 kg 2 0 m 200 kg 2 5 m 150 kg Bevestiging aandrijfarm 1 Bevestig de motorarm aan het midden van de opener vanaf de onderkant 2 Draai de kappen vast met de schroef en de sluitrin...

Page 47: ...enste volledig gesloten positie zoals aangegeven in afbeelding 3 c Maak het tijdelijk vast aan de poortvleugel maak nog geen permanente verbinding met de poortvleugel om aanpassingen mogelijk te maken...

Page 48: ...endelen verwijdert u de plastic afdekking voert u de sleutel in en draait u hem 90 Trek de koppeling omhoog zie afbeelding 4 Om het ontkoppelingsmechanisme weer in te schakelen duwt u de koppeling oml...

Page 49: ...R 2 2 Voer de verlengkabel van de secundaire motor door n van de kabelwartels aan de onderkant van de primaire eenheid zie afbeelding 8 Zorg ervoor dat u de kant van de motor gebruikt waar de arm de k...

Page 50: ...4V SPEC 24VDC SYNC STBY UART LIMIT SW E LK FLA COMMAND IR SENSOR EDGE 24V BAT 8 2K SAFETY EDGE NC NO NO Stop Fully Open Partial Open LAMP 1 FLASH LAMP SE SE GND GND IR3 IN3 IN2 IN1 IR2 IR1 L L N N PE...

Page 51: ...penen AP op het display geeft de eerste beschikbare functie in het menu aan 2 Gebruik de knoppen en om tussen de functies te navigeren 3 Druk op de knop P om de gewenste functie te selecteren 4 De sta...

Page 52: ...egt in sluitingsrichting indien ge nstalleerd aan de linkerkant standaard Motor 2 beweegt in sluitingsrichting indien ge nstalleerd aan de rechterkant standaard Motor 2 beweegt in sluitingsrichting in...

Page 53: ...met n motor worden de acties vleugel 2 niet gebruikt De volgende instellingen zijn geprogrammeerd gedurende de geavanceerde de leermodus 1 Reislengte van positie VOLLEDIG GESLOTEN tot VOLLEDIG OPEN 2...

Page 54: ...myQ werking 2 Cre er een account Download de gratis myQ app uit de App Store of Google Play Store en cre er een account Als u al een account heeft gebruik dan uw gebruikersnaam en wachtwoord 3 Registr...

Page 55: ...zonderlijk worden geprogrammeerd OPMERKING Onder de instellingen 01 02 en 03 wordt de TTC timer overbrugd door een invoercommando en zal de poort SLUITEN Onder instelling 06 wordt het aftellen van de...

Page 56: ...omkering en stop Omkering terug naar de eindpositie standaard Gedurende de beweging sluiten keert de poort bij een impact om naar de positie openen Gedurende de beweging openen bij impact keert de poo...

Page 57: ...ren aan de ingestelde tijd toegevoegd Om de teller te resetten nadat het onderhoud is uitgevoerd volstaat het de cycli nog een keer te programmeren geen teller standaard 1 000 cycli 2 000 cycli cycli...

Page 58: ...instellingen Alle instellingen behalve het radiogeheugen worden gewist Zie pagina 18 P S P S P S P S III I I I III I I I 2 sec III I I I of of 7 PROGRAMMERING 7 7 15d Kracht motoren 1 en 2 in de richt...

Page 59: ...kan de soft stopsnelheid worden aangepast ten opzichte van de standaardwaarden die tijdens de leerfase zijn ingesteld De soft stopsnelheid is 50 van de standaardsnelheid zoals standaard ingesteld De...

Page 60: ...akel de stroom gedurende 20 seconden uit en reset om te controleren of het bedieningspaneel zich herstelt Indien niet verander het bedieningspaneel F6 Poort gaat achteruit tijdens het sluiten Laag bat...

Page 61: ...ties Uw wettelijke rechten worden door deze fabrieksgarantie niet aangetast Zie www liftmaster eu voor de garantievoorwaarden Onze elektrische en elektronische apparatuur mag niet met het huisvuil wor...

Page 62: ...Chamberlain GmbH Saar Lor Lux Str 19 66115 Saarbr cken Germany WEEE Reg Nr DE66256568 www liftmaster eu info liftmaster eu 2021 all rights reserved 114A5439...

Reviews: