5
5.2 Determine the Position of the Post Bracket
1.
Determine the A, B and C dimensions based on the opening angle provided in Table 1 to confirm the position where the post bracket will be mounted.
NOTE:
All crushing points must be secured by an entrapment protection according to EU: EN 12453, EN 60335-2-103; GB (UK, NI): BS EN 12453, BS EN 60335-2-103.
AA250EVK
Example installation
AA250EVK
1.5 m
250 kg
2.0 m
200 kg
2.5 m
150 kg
Operator Arm Mounting
1. Attach the motor arm to the center of the opener from
the underside.
2. Secure the caps with the screw and washer.
175 mm
265 mm
250 mm
280 mm
Picture 1
13 mm
54 mm
30 mm
159 mm
Ø 8.5 mm
96 mm
Ø 8.5 mm
100 mm
60 mm
20 mm
A
B
C
Opening angle
mm
90°
150-300
390-540
0-300
120°
300-350
300-350
0-25
Table 1
min. 200 mm
20 mm
A
min. 420 mm
C
B
max. 120°
48.5 mm
Herewith you start mechanical installation of the gate operator.
5. MECHANICAL INSTALLATION
5.1 Dimensions of Gate and Operator