HD32.1
- 149 -
V2.1
14.1
A
AND
B
O
PERATING
P
ROGRAMS
P
ROBES
A:
M
ICROCLIMATE
A
NALYSIS
B:
D
ISCOMFORT
A
NALYSIS
TP3207
Pt100 sensor temperature probe. Probe stem Ø 14mm, length 140 mm. Cable
length 2 meters. Complete with SICRAM module.
Used for the following indexes calculation:
IREQ, WCI, DLE, RT, PMV, PPD,
WBGT, SR
. Used for the average radiation temperature calculation.
TP3275
Pt100 sensor globe thermometer probe, globe Ø 150 mm.
Stem Ø 14 mm, length 110 mm. Cable length 2 meters. Complete with SICRAM
module.
Used for the measurement of:
Average radiation temperature, WBGT
.
TP3276
Pt100 sensor globe thermometer probe, globe Ø 50 mm.
Stem Ø 8 mm, length 110 mm. Cable length 2 meters. Complete with SICRAM
module.
Used for the measurement of:
Average radiation temperature, WBGT
.
TP3227K
Temperature probe composed of 2 standalone temperature probes, Pt100 sensor.
Stem Ø 14 mm, length 500 mm. Cable length 2 meters. Complete with dual
SICRAM module and telescopic rod Ø 14 mm, length 450 mm TP3227.2.
Used for the measurement
of
local discomfort due to vertical temperature
gradient
. It can be used to study standing or seated persons. The probe height can
be adjusted.
TP3227PC
Temperature probe is composed of 2 standalone temperature probes, Pt100 sensor,
one for floor level temperature measurement (Ø 70 mm, height 30 mm), the other
for temperature measurement at ankle height (Ø 3 mm, height 100 mm). Cable
length 2 meters. Complete with dual SICRAM module.
Used for the measurement
of
local discomfort due to vertical temperature
gradient
.
TP3207P
Pt100 sensor temperature probe for floor level temperature measurement (Ø 70
mm, height 30 mm). Cable length 2 meters. Complete with SICRAM module.
Used for the measurement
of
local discomfort due to vertical temperature
gradient
.
TP3207TR
Probe for radiant temperature measurement. Probe stem Ø 16 mm, length 250
mm. Cable length 2 meters. Complete with SICRAM module.
Used
to
assess the unsatisfied with the radiant asymmetry percentage
.
AP3203
Omni directional hot-wire probe. Measurement range: Wind speed 0.1÷5 m/s,
temperature
0°C…+80°C
. Probe stem Ø 8 mm, length 230 mm. Cable length 2
meters. Complete with SICRAM module.
Used for the following indexes calculation:
IREQ, WCI, DLE, RT, PMV, PPD,
SR
. Used for the average radiation temperature calculation.
AP3203-F
Omni directional hot-wire probe. Measurement range: Wind speed 0.1÷5 m/s,
temperature
-30°C…+30°C
. Probe stem Ø 8 mm, length 230 mm. Cable length 2
meters. Complete with SICRAM module.
Used for the following indexes calculation:
IREQ, WCI, DLE, RT, PMV, PPD,
SR
. Used for the average radiation temperature calculation.
Summary of Contents for HD32.1
Page 6: ...HD32 1 6 V2 1 Thermal Microclimate HD32 1...
Page 78: ...HD32 1 78 V2 1 MIN 350 MAX 1020 120 AP471 S4...
Page 106: ...HD32 1 106 V2 1 Moderate Environment Norm ISO 7730...
Page 107: ...HD32 1 107 V2 1 Moderate Environment Norm ISO 7730...
Page 108: ...HD32 1 108 V2 1 Moderate Environment Norm ISO 7730...
Page 109: ...HD32 1 109 V2 1 Moderate Environment Norm ISO 7730...
Page 110: ...HD32 1 110 V2 1 Moderate Environment Norm ISO 7730...
Page 111: ...HD32 1 111 V2 1 Moderate Environment Norm ISO 7730...
Page 112: ...HD32 1 112 V2 1 12 2 WARM ENVIRONMENT Norm ISO 7243 Norm ISO 7243...
Page 113: ...HD32 1 113 V2 1 Warm Environment Norm ISO 7243...
Page 114: ...HD32 1 114 V2 1 Warm Environment Norm ISO 7243 Norm ISO 7243...
Page 115: ...HD32 1 115 V2 1 Warm Environment Norm ISO 7243...
Page 116: ...HD32 1 116 V2 1 Warm Environment Norm ISO 7243...
Page 117: ...HD32 1 117 V2 1 Warm Environment Norm ISO 7243...
Page 118: ...HD32 1 118 V2 1 12 3 DISCOMFORT ANALYSIS Norm ISO 7730 Norm ISO 7730...
Page 119: ...HD32 1 119 V2 1 Discomfort Analysis Norm ISO 7730...
Page 120: ...HD32 1 120 V2 1 Discomfort Analysis Norm ISO 7730...
Page 121: ...HD32 1 121 V2 1 Discomfort Analysis Norm ISO 7730...
Page 122: ...HD32 1 122 V2 1 Discomfort Analysis Norm ISO 7730...
Page 123: ...HD32 1 123 V2 1 Discomfort Analysis Norm ISO 7730...
Page 124: ...HD32 1 124 V2 1 Discomfort Analysis Norm ISO 7730...
Page 125: ...HD32 1 125 V2 1 12 4 HOT ENVIRONMENT Norm ISO 7933 Norm ISO 7933...
Page 126: ...HD32 1 126 V2 1 Hot Environment Norm ISO 7933...
Page 127: ...HD32 1 127 V2 1 Hot Environment Norm ISO 7933...
Page 128: ...HD32 1 128 V2 1 Hot Environment Norm ISO 7933...
Page 129: ...HD32 1 129 V2 1 Hot Environment Norm ISO 7933...
Page 130: ...HD32 1 130 V2 1 Hot Environment Norm ISO 7933...
Page 131: ...HD32 1 131 V2 1 Hot Environment Norm ISO 7933...
Page 132: ...HD32 1 132 V2 1 12 5 COLD ENVIRONMENT Norm ISO 11079 Norm ISO 11079...
Page 133: ...HD32 1 133 V2 1 Cold Environment Norm ISO 11079...
Page 134: ...HD32 1 134 V2 1 Cold Environment Norm ISO 11079...
Page 135: ...HD32 1 135 V2 1 Cold Environment Norm ISO 11079...
Page 136: ...HD32 1 136 V2 1 Cold Environment Norm ISO 11079...
Page 137: ...HD32 1 137 V2 1 Cold Environment Norm ISO 11079...
Page 138: ...HD32 1 138 V2 1 Cold Environment Norm ISO 11079...
Page 139: ...HD32 1 139 V2 1 Cold Environment Norm ISO 11079...
Page 140: ...HD32 1 140 V2 1 12 6 PHYSICAL QUANTITIES...
Page 153: ...HD32 1 153 V2 1 NOTES...
Page 154: ...HD32 1 154 V2 1 NOTES...
Page 155: ......