Instructions

1.

 Batteries are pre-installed in the thermometer. An extra battery is included with the 

thermometer for your convenience.

2.

 Before using the thermometer pull out the protective film from the front panel.

3.

 To turn on the thermometer unfold the probe from the housing and the LCD will 

display all options, and then the current temperature.

4.

 The default temperature scale is set to Fahrenheit. To switch to Celsius press the 

ºF/ºC 

key.

5.

 The thermometer comes precalibrated and ready to use. You can re-calibrate it 

anytime if you believe the temperatures are inaccurate using the ice-bath method. 
Refer to the instructions on the reverse side to create a proper ice water bath. 
Stick the probe in the ice bath and hold the 

CAL

 button for 5 seconds. 

"CALL"

 

will display on the LCD indicating it is in calibration mode. If the display reads 
"ERR" it means the water is too warm for the thermometer to be calibrated. If that 
is the case add more ice to bring the temperature down to within a few degrees 
of 32ºF/0ºC and press the 

CAL

 button again. While in calibration mode, use the 

ºF/ºC

 button to increase the digit and the 

HOLD

 button to decrease the digit until 

you reach 32ºF/0ºC. After several seconds of non-activity the display will reset to 
normal operation.

6.

 To use Data-hold press the 

HOLD

 key before removing the probe from product. 

This will hold the temperature reading until the button is pressed again.

7.

 To display the minimum or maximum temperature press the 

MIN/MAX

 key for 3 

seconds. The 

MAX

 indicator along with the maximum temperature reading will 

appear on the LCD. Press again and 

MIN

 indicator along with the minimum saved 

temperature reading appears on the LCD. To reset the 

MIN/MAX

 temperatures, 

get the LCD in either 

MIN

 or 

MAX

 modes as explained above. Press and hold the 

MIX/MAX

 button for 3 seconds. The screen will briefly show "

--.-

"  signal it has 

been reset and that the new

 MIN/MAX

 temperature readings have been saved.

8.

 To turn on the LCD back light press the 

 key. It will turn off after several 

seconds.

Operation

  Hand wash the metal probe in soapy water

• 

Sterilize metal probe by using alcohol wipe to sanitize.

Warnings and Precautions

  DO NOT LEAVE THE THERMOMETER IN THE OVEN WHILE COOKING.

  DO NOT IMMERSE THERMOMETER IN WATER

  DO NOT TOUCH HOT PROBE WITH BARE HANDS.

Remove the 

Protective Film

LCD Backlight

Calibration Mode

HOLD, MAX & MIN