background image

1

www.deltatrak.com

Before you begin

     

Check Inside the Box                                         Qty

Thermometer 

    1

Glycol 

Bottle 

Sensor    1

Alkaline 1.5v AA Battery  

 

 

 

1

    

Install a New Battery

  

  

      

      

 •  Open the battery door located on the back side of the enclosure by 

           removing the retaining screw
       •  Observe and follow the battery polarity (+/-)
       •  Insert the battery into the battery holder
          The LCD will light up and you will hear a beep. Then the device displays 
          the temperature reading from the sensor and the current Max and Mi 
          readings. 

 

       •  Close the battery door and tighten the retaining screw

     

Summary of Contents for FlashCheck 12237

Page 1: ...Model 12237 User Guide Certified Min Max Alarm Thermometer...

Page 2: ......

Page 3: ...y LCD Control Buttons Basic Features Display Modes Changing the Display Modes Resetting the Min Max Readings Clearing the Alarm Indication Configuring the Thermometer Entering the Configuration Mode N...

Page 4: ...door located on the back side of the enclosure by removing the retaining screw Observe and follow the battery polarity Insert the battery into the battery holder The LCD will light up and you will hea...

Page 5: ...rigger reading Down Arrow Use to decrease a set point value Note The instrument has no power off button so if it needs to be stored without power then the battery must be removed 1 Configuration Menu...

Page 6: ...Max Min memory Alarm Indication Alarm indication must be enabled in the configuration menu and the High Low Alarm set points must be set When the sensor s reading exceeds the Alarm set points Alarm co...

Page 7: ...arm setting or click the Clear button to set it to zero Alarm Delay Menu 3 The alarm indication can be delayed after a number of consecutive readings in alarm up to 199 readings The delay setting is d...

Page 8: ...currently seleced scale Battery replacement The Thermometer can operate with low battery indication for at least 10 days During that time only one bar is visible on the battery level indicator When no...

Page 9: ...y Control Button Default Screen Configuration Mode Screen CLEAR If an Alarm has been triggered pressing CLEAR resets the Alarm indicator Bell icon and clears the High Low flashing indicator from the d...

Page 10: ...Menu option 4 3 Alarm Delay 0 Select up to 199 consecutive 30 second delay intervals 4 Enable Alarm On or Off On On Alarm is enabled The Menu Options 1 2 become operational When an Alarm is triggered...

Page 11: ...8 www deltatrak com Notes...

Page 12: ...ll at its option either repair or replace hardware products that prove to be defective if a notice to that effect is received within the warranty period DeltaTrak makes no other warranties or represen...

Reviews: