HLP-Pump Faultfinding list 

 

Important: Always disconnect the pump from mains, before attempting any repairs

Repairs on electrical components only to be carried out by qualified personnel. 

 

Symptom 

Cause 

Action 

 

 

 

Pump does not 
start 

No power 

Check plug, lead, socket, fuse 

3 stage switch in neutral 

Move switch to desired stage 

Capacitor faulty 

Replace  

Lead, plug, fuse faulty 

Replace 

Thermo switch in stator faulty 

Replace 

 

 

 

Pump impeller 
rotates but 
insufficient or no 
water flow        

Pump installation faulty, non return 
valve faulty  

Repair, replace 

Shut off valve in suction or pressure line 
closed or faulty 

Open / check for correct function 

Foreign bodies in suction line or impeller  Clean 

Air pocket in suction line / pump 
housing 

Bleed, by starting and stopping the 
pump several times. Increase water 
level in filter sump 

Suction line not sealed 

Tighten all connections 

 

  

  

Pump is noisy  

Foreign bodies in pump housing,impeller  Clean 

Air bubbles in pumps water flow 

Check suction line for leaks, check o-
rings-shut off valve in suction line 

  

  

  

After stopping 
pump does not 
restart 

The air / water mix witch siphons back 
created air pockets in the pump housing 
or piping 

Bleed, start and Stop the pump several 
time modify pipe system 

 

Pump produces 
air bubbles 

Suction line not properly sealed 

Check suction line for leak, tighten all 
connections, replace O-rings 

Water level in filter sump not high 
enough 

Increase water level 

O-ring old  

Replace O-ring  

  

  

  

Pump stator is 
heating up and 
Stops 

Insufficient water in sump 

Correct water level 

Air pockets in rotor housing. Causing 
friction in the ceramic bearing 

Allow the pump to cold down for about 
30 min. start the pump close the shut 
off valve in the pressure line, slacken 
the silver plug in face of the stator and 
allow the air to escape, frighten the plug 
open the shut off valve. If required 
repeat until all air is removing and pump 
runs normal 

  

  

  

Pump operates 
with increased 
temperature 

Lime scale deposits in rotor / pump 
housing   

Remove Pump, close suction side 
opening, fill pump with lime scale 
remover. After the gas bubbles have 
stopped to appear at the pumps 
pressure side, drain the pump housing 
and clean with tap water. Please 
observe all required safety measures 
when using lime scale remover 

 
 
 
 
 
 

Summary of Contents for HLP 4040

Page 1: ...P pumps Pompe HLP Pompes HLP HLP Bedienungsanleitungen und Ersatzteillisten Operating instructions and Spare parts lists Istruzioni d uso e parti di ricambio Instructions d emploi et Accessoires et pi...

Page 2: ...e durchh ngt Bild Auf diese Weise tropft das Wasser unter der Steckdose vom Kabel ab und kann nicht mit dieser in Ber hrung kommen Wenn der Stecker oder die Steckdose nass wird NICHT das Kabel herausz...

Page 3: ...t eine Wartung Reinigung nicht erforderlich Im Seewasser ist jedoch durch den Betrieb von Kalkreaktoren und Kalkwassermischern eine Verkalkung der Pumpen nicht auszuschlie en Um einen stillstand durch...

Page 4: ...dk rper im Turbinengeh use Fremdk rper entfernen Saugkorb einbauen Pumpe saugt Luft Saugleitung Verschraubung auf Dichtheit pr fen Pumpe f rdert nicht nach Stillstand Pumpengeh use voll Luft durch r c...

Page 5: ...omatisch wieder an es sei denn die Laufeinheit ist blockiert Ursachen f r die Erw rmung k nnen sein a Verkalkung der Pumpe b Fremdk rper im Pumpengeh use laufrad c Luft im Rotorraum der Pumpe Zu a Im...

Page 6: ...the receptacle or the connector if an extension cord is used to prevent water travelling along the cord and coming in contact with the receptacle If the plug or socket does get wet DON T unplug the c...

Page 7: ...intenance The HLP pumps are basically maintenance free When used in marine aquaria a build up of lime scale is possible It is advisable to clean the pump from time to time every 6 to 12 month with a c...

Page 8: ...suction line After stopping pump does not restart The air water mix witch siphons back created air pockets in the pump housing or piping Bleed start and Stop the pump several time modify pipe system P...

Page 9: ...rn the regulator to programme mode the blue LED lights up 50 pre programmed interval times of between 5 seconds and 15 minutes are called up After these 50 cycles have been completed the process is re...

Page 10: ...ella presa o della spina di collegamento nel caso si usi una prolunga impedendo cos che l acqua gocciolando lungo il cavo venga a contatto con la presa Se la presa o la spina si bagna NON disinserire...

Page 11: ...ne pulizia non necessaria Tuttavia negli acquari marini non da escludere la formazione di calcare nella pompa dovuta all uso di reattori di calcio e miscelatori Acqua di calce Per evitare il mancato f...

Page 12: ...rbina eliminare i corpi estranei installare una griglia d aspirazione la pompa aspira aria verificare la tenuta del tubo aspirante e del collegamento a vite Dopo un periodo di inattivit la pompa non f...

Page 13: ...cende automaticamente a meno che la girante non sia bloccata Le cause di un surriscaldamento della pompa possono essere a Incrostazione della pompa b Presenza di corpo estraneo nella pompa girante c A...

Page 14: ...s la prise de courant en cas d emploi d une rallonge De cette mani re l eau s gouttera sous la prise de courant du c ble et ne pourra pas entrer en contact avec celui ci Si la fiche ou la prise de cou...

Page 15: ...ible dans le commerce Ne pas d monter la pompe pour le nettoyage D tachez le c t aspiration de la pompe et remplissez l enveloppe de la pompe du produit anti calcaire Ensuite rincez la pompe sous l ea...

Page 16: ...RU 1 2 a b c d e 3 4 5 6 7 8 9 10 11...

Page 17: ...HLP 4040 HLP 4745 HLP 5250 HLP 8070 HLP 8070S 4 200 5 000 6 000 7 000 8 300 3 5 4 3 5 1 6 4 7 8 60 79 87 130 158 3 3 3 3 3 230 240 230 240 230 240 230 240 230 240 32 32 32 40 40 25 25 32 32 32 165 120...

Page 18: ...RU HLP 3 HLP Deltec HLP...

Page 19: ...RU 3 Aus 1 2 8 20 3 Mode 50 5 15 50 Deltec HLP 4 5 4 4...

Page 20: ...tec Aquarium Solutions Europe Hamweg 88 9617 AT Harkstede Nederland les Pays Bas Greece Switzerland french part Israel Reefish Business Aqua Home SeaShell Ltd Thessalonikis 80 Oraiokastro 6 Rue de la...

Reviews: