background image

EN 

 

 

HLP interval pumps

 

 

It is common knowledge that fishes and in particular most invertebrates benefit from strong, irregular water 
movement  in  a  marine  aquarium. 

  HLP  interval  pumps 

are  almost  inaudible;  they  are  free  of  wear 

parts and are efficient in operation. 

 

Operating instructions 

The 

 HLP pumps 

come with a standard 3 stage selector switch. The interval control is connected to 

the pump through a control cable. A potentiometer with an on/off function will start/stop the interval mode 
and allows setting of the interval time span. 

 

Standard pump operation 

-

 

Select required performance at the pump 3 stage selector. 

-

 

Switch off potentiometer at the interval control unit 

 

Interval operation 

First, the pump is set to the lowest power setting (level 1 or 2). Then the interval control is switched on by 
turning  the  regulator  in  a  clockwise  direction  (yellow/green  LED  lights  up).   The  interval  time  can  be  set  to 
between 8 seconds and 20 minutes.  If the green LED lights up, the level selected at the pump is active.  If 
the yellow LED lights up, level 3 is active.  
If you turn the regulator to “programme mode” (the blue LED lights up), 50 pre-programmed interval times 
of between 5 seconds and 15 minutes are called up.  After these 50 cycles have been completed the process 
is repeated.  

 

 HLP interval pumps 

are available in 5 sizes, from 4500 litre/h to 9000 litre/h 

 

Please note 

The  water  flow  of  the  pump  is  determined  by  the  water  head  as  well  as  the  flow  resistance  in  the  piping 
system. Non-return valves, long pipes and a large number of elbows can reduce the water flow considerably.

 

 

Maintenance 

The 

 HLP pumps

 are basically maintenance free.  

When used in marine aquaria a build-up of lime scale is possible. It is advisable to clean the pump from time 
to time (every 6 to 12 month) with a commercially available lime scale remover. Do not dismantle the pump 
for this purpose. 
Plug the suction side of the pump and fill the housing with lime scale remover. 
Afterwards flush the pump with tap water. 

 

Safety hints 

-

 

Never try to use the 

 HLP pump 

submerged in water. 

-

 

Disconnect from mains when working on the pump or the pumps pipe work. 

-

 

Do not carry the pump on its lead 

-

 

Install in such a way that accidental flooding is not possible. 

-

 

Operate the pump only with a ground fault circuit interrupter (<30mA). 

 

Removing of the plug invalidates the warranty! 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HLP 4040

Page 1: ...P pumps Pompe HLP Pompes HLP HLP Bedienungsanleitungen und Ersatzteillisten Operating instructions and Spare parts lists Istruzioni d uso e parti di ricambio Instructions d emploi et Accessoires et pi...

Page 2: ...e durchh ngt Bild Auf diese Weise tropft das Wasser unter der Steckdose vom Kabel ab und kann nicht mit dieser in Ber hrung kommen Wenn der Stecker oder die Steckdose nass wird NICHT das Kabel herausz...

Page 3: ...t eine Wartung Reinigung nicht erforderlich Im Seewasser ist jedoch durch den Betrieb von Kalkreaktoren und Kalkwassermischern eine Verkalkung der Pumpen nicht auszuschlie en Um einen stillstand durch...

Page 4: ...dk rper im Turbinengeh use Fremdk rper entfernen Saugkorb einbauen Pumpe saugt Luft Saugleitung Verschraubung auf Dichtheit pr fen Pumpe f rdert nicht nach Stillstand Pumpengeh use voll Luft durch r c...

Page 5: ...omatisch wieder an es sei denn die Laufeinheit ist blockiert Ursachen f r die Erw rmung k nnen sein a Verkalkung der Pumpe b Fremdk rper im Pumpengeh use laufrad c Luft im Rotorraum der Pumpe Zu a Im...

Page 6: ...the receptacle or the connector if an extension cord is used to prevent water travelling along the cord and coming in contact with the receptacle If the plug or socket does get wet DON T unplug the c...

Page 7: ...intenance The HLP pumps are basically maintenance free When used in marine aquaria a build up of lime scale is possible It is advisable to clean the pump from time to time every 6 to 12 month with a c...

Page 8: ...suction line After stopping pump does not restart The air water mix witch siphons back created air pockets in the pump housing or piping Bleed start and Stop the pump several time modify pipe system P...

Page 9: ...rn the regulator to programme mode the blue LED lights up 50 pre programmed interval times of between 5 seconds and 15 minutes are called up After these 50 cycles have been completed the process is re...

Page 10: ...ella presa o della spina di collegamento nel caso si usi una prolunga impedendo cos che l acqua gocciolando lungo il cavo venga a contatto con la presa Se la presa o la spina si bagna NON disinserire...

Page 11: ...ne pulizia non necessaria Tuttavia negli acquari marini non da escludere la formazione di calcare nella pompa dovuta all uso di reattori di calcio e miscelatori Acqua di calce Per evitare il mancato f...

Page 12: ...rbina eliminare i corpi estranei installare una griglia d aspirazione la pompa aspira aria verificare la tenuta del tubo aspirante e del collegamento a vite Dopo un periodo di inattivit la pompa non f...

Page 13: ...cende automaticamente a meno che la girante non sia bloccata Le cause di un surriscaldamento della pompa possono essere a Incrostazione della pompa b Presenza di corpo estraneo nella pompa girante c A...

Page 14: ...s la prise de courant en cas d emploi d une rallonge De cette mani re l eau s gouttera sous la prise de courant du c ble et ne pourra pas entrer en contact avec celui ci Si la fiche ou la prise de cou...

Page 15: ...ible dans le commerce Ne pas d monter la pompe pour le nettoyage D tachez le c t aspiration de la pompe et remplissez l enveloppe de la pompe du produit anti calcaire Ensuite rincez la pompe sous l ea...

Page 16: ...RU 1 2 a b c d e 3 4 5 6 7 8 9 10 11...

Page 17: ...HLP 4040 HLP 4745 HLP 5250 HLP 8070 HLP 8070S 4 200 5 000 6 000 7 000 8 300 3 5 4 3 5 1 6 4 7 8 60 79 87 130 158 3 3 3 3 3 230 240 230 240 230 240 230 240 230 240 32 32 32 40 40 25 25 32 32 32 165 120...

Page 18: ...RU HLP 3 HLP Deltec HLP...

Page 19: ...RU 3 Aus 1 2 8 20 3 Mode 50 5 15 50 Deltec HLP 4 5 4 4...

Page 20: ...tec Aquarium Solutions Europe Hamweg 88 9617 AT Harkstede Nederland les Pays Bas Greece Switzerland french part Israel Reefish Business Aqua Home SeaShell Ltd Thessalonikis 80 Oraiokastro 6 Rue de la...

Reviews: