background image

INSTALLATION

CONSIDERATIONS FOR INSTALLATION

A

B

A

B

C

D

Opening

angle

A

B

Cu

90

80

80

160

90

90

180

100

100

200

100

150

250

100

110

110

220

120

120

240

120

100

220

Opening

angle

A

B

Cu

110

130

130

260

140

140

280

150

150

300

90°  con
corsa
diponibile
400mm

160

160

320

175

175

350

190

190

380

200

200

400

·

  The installation and testing operations must be performed solely by qualified personnel in order
  to guarantee the proper and safe operation of the automatic gate.

·

   The company declines any responsibility for damage caused by incorrect installations due to
  incompetence and/or negligence.

·

  Before assembling the automatism, check that the gate is in perfect working order, hangs well
  on its hinges  and is suitably lubricated. It must also comply with the safety standards in force
  in the country of installation..

1.   Before  fastening  the  brackets  provided,  establish  the  coordinates  using  the  data  given  in

Table 1,

bearing in mind that they are valid if the operator is at maximum extension minus one

  centimetre of the available stroke

(CD)

 when the gate is closed to obtain maximum working

  efficiency.

2.   Data

B

 in the table, with reference to the single values

A

, are to be considered as values

      (recommended).
3.  To anchor the piston, use the fastening brackets provided.

COORDINATES AND TABLE

1.  Establish  coordinates

A  +  B

that are   to be used.

2.

Note:

The available stroke (CD) of

the operator must never be equal or

      greater than the stroke used (CU)
3.  The sum of coordinates

A + B

,

      establishes the stroke used

CU

.

TABLE 1

Note1: A+B = CU (Stroke used)      CD = (Available stroke) = 400mm

Summary of Contents for AMICO 400BZ

Page 1: ...installing thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 ...

Page 2: ...3 TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 5 6 TROUBLESHOOTING 7 SAFETY PRECAUTIONS 8 PACKING CONTENTS 1 OPERATOR 1 KIT FASTENING PLATES AND RELATIVE ACCESSORIES 1 UNLOCKING KEY 1 CONDENSER 230Vca ...

Page 3: ...ng temperature 20 C 55 C weight 8 Kg Protection rating IP 55 Opening time 90 15 sec Rod stroke 400 mm Force of thrust 1500 N Motor current input 1 5 A 1 A 2 5 VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS 4 3 1 1 5 6 7 8 Optimal installation 1 Operator 2 External photocell 3 Flashing warning light 4 Antenna 5 Internal photocell 6 Electronic control unit 7 Key switch 8 Remote control TECHNICAL...

Page 4: ...DIMENSIONS TYPICAL CONNECTION AND CABLE SECTION 2X1 5mm2 24 Vdc 4X1 5mm2 230 Vca 2X0 75mm2 4X0 75mm2 4X0 75mm2 2X0 75mm2 105 mm 825 mm 110 mm 400 mm 3X1 5mm2 230V Line RX Photocell TX Photocell ...

Page 5: ...ngs well on its hinges and is suitably lubricated It must also comply with the safety standards in force in the country of installation 1 Before fastening the brackets provided establish the coordinates using the data given in Table 1 bearing in mind that they are valid if the operator is at maximum extension minus one centimetre of the available stroke CD when the gate is closed to obtain maximum...

Page 6: ...S FIG 1 FIG 2 40mm A B Fix the back plate to the pillar FIG 1 Anchor the rear part of the piston to the plate and fasten it firmly FIG 2 1 Fit the anchor plate onto the piston fig 4 2 Close the gate 3 Move the piston with the plate already fitted towards the gate 4 Move the fitting to limit stop then move it back by approximately 1 cm and mark the position of the plate 5 realize the same operation...

Page 7: ...g or the beam is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote control the gate doesn t open but works with the key command The remote control has not been memorised or the battery is flat Carry out the remote control learning procedure on the radio receiver or replace the battery with a new one The gate starts but stops immediately The fo...

Page 8: ...ntegrity safety and operation in the event incompatible devices and or components are installed Solely original spare parts should be used for repairs and replacements The installer must provide all the information relating to the operation maintenance and use of the individual parts components and system as a whole WARNINGS FOR THE USER Read the instructions and enclosed documentation carefully T...