background image

R

ev

. 1

-07

/11

 ING

SAFETY PRECAUTIONS

These warnings are an essential, integral part of the product and must be given to the user. They

provide important indications on the installation, use and maintenance and must be read carefully.

This form must be preserved and passed on to subsequent users of the system. The incorrect

installation or improper use of the product may be dangerous.

INSTALLATION INSTRUCTIONS

• 

  The installation must be performed by professionally skilled personnel and in compliance with

  current local, state, national and European legislation.

• 

  Before beginning the installation, check the integrity of the product.

• 

  The laying of cables, electrical connections and adjustments must be workmanlike performed.

• 

  The packing materials (cardboard, plastic, polystyrene, etc.) are a potential hazard and should

  be disposed of correctly and not left within reach of children.

• 

  Do not install the product in potentially explosive environments or environments disturbed by

  electromagnetic fields. The presence of inflammable gases or fumes is a grave danger to

  safety.

• 

  Set up a safety device for overvoltage, a disconnecting and/or differential switch suitable for

  the product and conforming to current standards.

• 

  The manufacturer declines any and all responsibility for product integrity, safety and operation

  in the event incompatible devices and/or components are installed.

• 

  Solely original spare parts should be used for repairs and replacements.

• 

  The installer must provide all the information relating to the operation, maintenance and use of

  the individual parts, components and system as a whole.

WARNINGS FOR THE USER

• 

  Read the instructions and enclosed documentation carefully.

• 

  The product must be used for the express purpose for which it was designed. Any other use is

  considered improper and therefore hazardous. In addition, the information given in this

  document and in the enclosed documentation may be subject to modifications without prior

  notice. It is given as an indication only for product application. The company declines any

  responsibility for the above.

• 

  Keep products, devices, documentation and anything else provided out of reach of children.

  In the event of maintenance, cleaning, breakdown or faulty operation of the product, cut off the

  power and do not attempt to operate on the product. Contact solely the professionally skilled

  personnel responsible for these operations. Failure to adhere to the above indications may be

  dangerous.

1095 Budapest, Mester u. 34.

Tel.: *218-5542, 215-9771, 215-7550, 

216-7017, 216-7018  Fax: 218-5542

Mobil: 30 940-1970, 20 949-2688

  

1141 Budapest, Fogarasi út 77.

Tel.: *220-7940, 220-7814, 220-7959,

220-8881, 364-3428  Fax: 220-7940

E-mail: delton@delton.hu  Web: www.delton.hu

www.kaputnyitunk.hu

Mobil: 30 531-5454, 30 939-9989

Summary of Contents for AMICO 400BZ

Page 1: ...installing thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 ...

Page 2: ...3 TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 5 6 TROUBLESHOOTING 7 SAFETY PRECAUTIONS 8 PACKING CONTENTS 1 OPERATOR 1 KIT FASTENING PLATES AND RELATIVE ACCESSORIES 1 UNLOCKING KEY 1 CONDENSER 230Vca ...

Page 3: ...ng temperature 20 C 55 C weight 8 Kg Protection rating IP 55 Opening time 90 15 sec Rod stroke 400 mm Force of thrust 1500 N Motor current input 1 5 A 1 A 2 5 VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS 4 3 1 1 5 6 7 8 Optimal installation 1 Operator 2 External photocell 3 Flashing warning light 4 Antenna 5 Internal photocell 6 Electronic control unit 7 Key switch 8 Remote control TECHNICAL...

Page 4: ...DIMENSIONS TYPICAL CONNECTION AND CABLE SECTION 2X1 5mm2 24 Vdc 4X1 5mm2 230 Vca 2X0 75mm2 4X0 75mm2 4X0 75mm2 2X0 75mm2 105 mm 825 mm 110 mm 400 mm 3X1 5mm2 230V Line RX Photocell TX Photocell ...

Page 5: ...ngs well on its hinges and is suitably lubricated It must also comply with the safety standards in force in the country of installation 1 Before fastening the brackets provided establish the coordinates using the data given in Table 1 bearing in mind that they are valid if the operator is at maximum extension minus one centimetre of the available stroke CD when the gate is closed to obtain maximum...

Page 6: ...S FIG 1 FIG 2 40mm A B Fix the back plate to the pillar FIG 1 Anchor the rear part of the piston to the plate and fasten it firmly FIG 2 1 Fit the anchor plate onto the piston fig 4 2 Close the gate 3 Move the piston with the plate already fitted towards the gate 4 Move the fitting to limit stop then move it back by approximately 1 cm and mark the position of the plate 5 realize the same operation...

Page 7: ...g or the beam is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote control the gate doesn t open but works with the key command The remote control has not been memorised or the battery is flat Carry out the remote control learning procedure on the radio receiver or replace the battery with a new one The gate starts but stops immediately The fo...

Page 8: ...ntegrity safety and operation in the event incompatible devices and or components are installed Solely original spare parts should be used for repairs and replacements The installer must provide all the information relating to the operation maintenance and use of the individual parts components and system as a whole WARNINGS FOR THE USER Read the instructions and enclosed documentation carefully T...

Reviews: