Page 1: ...FOR RESIDENTIAL USER MANUAL SLIDING GATE OPENERS PL500 24V DC MOTOR ...

Page 2: ...ystem Learning and LED Display 3 4 Programmable Function Settings 3 5 Testing and Checking 3 6 SW2 SW6 Setting 4 Technical Characteriestics 4 1 Tenical Data Sheet of Series 4 2 PH 1 Photocell Data Sheet 4 3 PR 1 Transmitter Data Sheet 4 4 PF 1 Flashing Light Data Sheet 4 5 PRB 1 External Receiver Box Data Sheet 5 Additional Information 5 1 Wire Connection Of PH 1 Photocell Safety Beam 5 2 Wire Con...

Page 3: ...he gates works properly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated accid...

Page 4: ...afety photo Sensor 4 Flashing light a Operation gear b Limit switch device c 24Vdc motor d Back up batteries e Release device f Control panel g Terminals of devices 2 Installation 3 4 2 3 e f g a b c d 2 2 Description Of Device INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL 3 1 ...

Page 5: ...2 3 Dimenstion Of Device 2 4 Installation Of Motor Gear And Gear Rack 100 25 50 25 1 2m 4 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL ...

Page 6: ...cedure as below Step1 Push the lid of release chamber and move rightward Step2 Insert the key and turn clockwise to unlock the device Step3 Turn counter clockwise of the bar to release the motor To restore the automation simply reverse the above procedure Step1 Step2 Step3 NO OK DX SX INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL 5 ...

Page 7: ...oving 6 6 7 9 9 6 8 9 6 9 10 11 PPB 1 PPB 1 PKS 1 PKS 1 3 4 PF 1 PF 1 AC INPUT 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 AC INPUT 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 6 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL LED1 Photocells LED2 Photocells LED3 RF Learn AC INPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 C lo s e S to p G N D P b P h P h 2 P h 1 G N D E ...

Page 8: ... mode and then wait for learning instructions ARN The system learning is in progress The Auto learning process of gate moving Gate open to the end stop close to the end stop LED 3 2 Sec LED 3 blink twice LED 3 OFF 1 Press 1 3 Sec Press 3 Sec Push 1 2 3 4 5 6 2 3 12 13 14 LED1 LED2 LED3 ON OFF 14 LED1 LED2 LED3 ON OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 LED1 LED2 LED3 ON OFF RUN The Boxer system is in n...

Page 9: ...ight Heavy 1 The factory setting is F3 1 1 The function can adjust the running speed of motor 2 The factory setting is F4 4 1 The function can adjust the running force of motor to be compatible with the gate weight 2 The factory setting is F5 4 3 The motor force value F5 1 2A F5 6 7A F5 2 3A F5 7 8A F5 3 4A F5 8 10A F5 4 5A F5 9 13A F5 5 6A 4 As over current setting 1 The function can adjust the t...

Page 10: ...tomatic closing time Photocell 1 Photocell 2 Stop opening Locks and on release reverses to open Locks and on release continues opening Logic F3 1 The reactions of the photocells when detecting obstacles Gate Status Closed Open Stop during moving Closing Opening Safety Edge Stop opening Stop opening closing Reverses to open for 2 seconds Reverses to close for 2 seconds Photocell 1 No effect Reloads...

Page 11: ...to ON if Stop 12 is not connected Otherwise switch to OFF if Stop is connected to any device Setting with SW2 Setting with SW2 No function 1 2 must switch to ON if Ph1 Ph2 are not connected to any devices Default Device Description coordinate with remote Remark SW2 SW2 ON OFF 2 4 Channel Transmitter 2 4 Channel Transmitter ON Button B is pedestrian mode If connected with external device EXT EXT 1 ...

Page 12: ...mperature Dimension Radio transmitter 433 92Mhz Rolling code 2 for single gate or dual gate operation 3V with one CR2032 button type lithium battery 20 50 71 5mm 33mm 14mm Application Installation Operating Temperature Dimension For outdoor use Wall mounted vertically 20 50 85mm 60 5mm 40 5mm Power Supply Radio Frequency Max remote memorized Dimensions Output terminals 12V 24V ac dc 433 92Mhz 200p...

Page 13: ... 6 3 A B C 3 Wiring connection TX Connect terminals 1 and 2 on the transmitter with the terminals GND and 24V on the PC200 PCB RX Connect terminals 1 2 and 4 on the receiver with the terminals GND 24V and phot1 on the PC200 PCB And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge See Figure 3 3 6 4 Figure 3 3 6 5 and Figure 3 3 8 5 Figure 3 3 6 4 Figure 3 3 6 5 CA CC NA N...

Page 14: ... press and hold Learn Button for 1 second the LED light should be ON If the LED does not response please check the cable connection again c Press and hold Button C on the remote for 1 second after the LED is ON The remote completed the memorizing process when LED light turns OFF 3 Device Testing Remote Memorization a Orange cable Signal 1 connect to terminal 10 Pb on the control board b Blue cable...